mlsanityData to 14 Oct 2026

Fast and Accurate Multiclass Inference for MI-BCIs Using Large Multiscale Temporal and Spectral Features

arXiv 1806.06823 ↗First posted 18 Jun 2018eess.SP q-bio.NCcited by 4

Not on the map. Why?

Abstract (arXiv)

Accurate, fast, and reliable multiclass classification of electroencephalography (EEG) signals is a challenging task towards the development of motor imagery brain-computer interface (MI-BCI) systems. We propose enhancements to different feature extractors, along with a support vector machine (SVM) classifier, to simultaneously improve classification accuracy and execution time during training and testing. We focus on the well-known common spatial pattern (CSP) and Riemannian covariance methods, and significantly extend these two feature extractors to multiscale temporal and spectral cases. The multiscale CSP features achieve 73.70±15.90% (mean± standard deviation across 9 subjects) classification accuracy that surpasses the state-of-the-art method [1], 70.6±14.70%, on the 4-class BCI competition IV-2a dataset. The Riemannian covariance features outperform the CSP by achieving 74.27±15.5% accuracy and executing 9x faster in training and 4x faster in testing. Using more temporal windows for Riemannian features results in 75.47±12.8% accuracy with 1.6x faster testing than CSP.

Key facts. Cited by 4 papers in the map (data through 14 Oct 2026). First posted on arXiv 18 Jun 2018.

Builds on

No reference list yet.

Built on by

Cited by year

Citing papers per year: 2021: 1; 2022: 2; 2023: 1.

4 papers.