Segmentation of Arterial Walls in Intravascular Ultrasound Cross-Sectional Images Using Extremal Region Selection
Not on the map. Why?
Abstract (arXiv)
Intravascular Ultrasound (IVUS) is an intra-operative imaging modality that facilitates observing and appraising the vessel wall structure of the human coronary arteries. Segmentation of arterial wall boundaries from the IVUS images is not only crucial for quantitative analysis of the vessel walls and plaque characteristics, but is also necessary for generating 3D reconstructed models of the artery. The aim of this study is twofold. Firstly, we investigate the feasibility of using a recently proposed region detector, namely Extremal Region of Extremum Level (EREL) to delineate the luminal and media-adventitia borders in IVUS frames acquired by 20 MHz probes. Secondly, we propose a region selection strategy to label two ERELs as lumen and media based on the stability of their textural information. We extensively evaluated our selection strategy on the test set of a standard publicly available dataset containing 326 IVUS B-mode images. We showed that in the best case, the average Hausdorff Distances (HD) between the extracted ERELs and the actual lumen and media were 0.22 mm and 0.45 mm, respectively. The results of our experiments revealed that our selection strategy was able to segment the lumen with ≤ 0.3 mm HD to the gold standard even though the images contained major artifacts such as bifurcations, shadows, and side branches. Moreover, when there was no artifact, our proposed method was able to delineate media-adventitia boundaries with 0.31 mm HD to the gold standard. Furthermore, our proposed segmentation method runs in time that is linear in the number of pixels in each frame. Based on the results of this work, by using a 20 MHz IVUS probe with controlled pullback, not only can we now analyze the internal structure of human arteries more accurately, but also segment each frame during the pullback procedure because of the low run time of our proposed segmentation method.
Key facts. Cited by 4 papers in the map (data through 7 Oct 2026). First posted on arXiv 10 Jun 2018.
Builds on
No reference list yet.
Built on by
Citing papers per year: 2021: 3; 2022: 1.
4 papers.
- 2021Product Re-identification System in Fully Automated Defect Detectioncited by 2
- 2021A Deep Learning-based Method to Extract Lumen and Media-Adventitia in Intravascular Ultrasound Imagescited by 0
- 2021Real-time Street Human Motion Capturecited by 0
- 2022Image Style Transfer: from Artistic to Photorealisticcited by 0
- 2022Image Style Transfer: from Artistic to Photorealistic12 Mar 2022
- 2021Real-time Street Human Motion Capture21 Dec 2021
- 2021Product Re-identification System in Fully Automated Defect Detection20 Dec 2021
- 2021A Deep Learning-based Method to Extract Lumen and Media-Adventitia in Intravascular Ultrasound Images21 Feb 2021