mlsanityData to 14 Oct 2026

An Analysis of Two Common Reference Points for EEGs

arXiv 1801.02474 ↗First posted 3 Jan 2018eess.SP cs.LG stat.MLcited by 4

Not on the map. Why?

Abstract (arXiv)

Clinical electroencephalographic (EEG) data varies significantly depending on a number of operational conditions (e.g., the type and placement of electrodes, the type of electrical grounding used). This investigation explores the statistical differences present in two different referential montages: Linked Ear (LE) and Averaged Reference (AR). Each of these accounts for approximately 45% of the data in the TUH EEG Corpus. In this study, we explore the impact this variability has on machine learning performance. We compare the statistical properties of features generated using these two montages, and explore the impact of performance on our standard Hidden Markov Model (HMM) based classification system. We show that a system trained on LE data significantly outperforms one trained only on AR data (77.2% vs. 61.4%). We also demonstrate that performance of a system trained on both data sets is somewhat compromised (71.4% vs. 77.2%). A statistical analysis of the data suggests that mean, variance and channel normalization should be considered. However, cepstral mean subtraction failed to produce an improvement in performance, suggesting that the impact of these statistical differences is subtler.

Key facts. Cited by 4 papers in the map (data through 14 Oct 2026). First posted on arXiv 3 Jan 2018.

Builds on

No reference list yet.

Built on by

Cited by year

Citing papers per year: 2022: 2; 2023: 0; 2024: 1; 2025: 1.

4 papers.