# Measurement-Error-Aware Causal Distributed-Lag Quantile Modeling of Indoor Air Pollution and Short-Term Lung-Function Deterioration

arXiv: https://arxiv.org/abs/2609.31646 · HTML: https://mlsanity.com/paper/2609.31646/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 3 of its 38 references that are in the map.
- First posted on arXiv 12 Sep 2026.

## Builds on (most cited first, 3 of 3)

- [Temporal Fusion Transformers for Interpretable Multi-horizon Time Series Forecasting](https://mlsanity.com/paper/1912.09363/) (2019)
- [Nonparametric methods for doubly robust estimation of continuous treatment effects](https://mlsanity.com/paper/1507.00747/) (2015)
- [Causal Inference for Continuous Multiple Time Point Interventions](https://mlsanity.com/paper/2305.06645/) (2023)

## Abstract (arXiv)

Low-cost indoor air-quality sensors could support personalized asthma prevention, but their nonlinear measurement error, delayed exposure effects, time-varying confounding, and heterogeneous lower-tail responses limit risk estimation. We present CAUSALQUANT-ASTHMA, a measurement-error-aware causal quantile distributed-lag framework for short-horizon peak expiratory flow analysis. Sparse reference measurements train a nonlinear calibration model; stabilized sequential generalized-propensity weights address measured exposure assignment; and a susceptibility-modulated, smooth, noncrossing quantile model estimates lag-specific and sustained-exposure contrasts. Because no authorized cohort simultaneously provided dense indoor sensing, reference co-location, and outcome-compatible longitudinal data, evaluation used five semi-synthetic panels with known counterfactual truth, 150 patients and 12,600 patient-days per realization. Across eight methods, CAUSALQUANT achieved a dose-response integrated absolute error of 0.304 plus or minus 0.094, improving 24.2 percent over the strongest measurement-error and propensity-weighted baseline. It also obtained the lowest overall pinball loss, 1.065, while maintaining zero quantile crossings and 78.1 percent coverage for the nominal 80 percent interval. Sensor calibration reduced held-out exposure RMSE by 33.7 percent. Stress tests quantified degradation under sensor noise, missing personal measurements, and hidden confounding. These findings establish methodological feasibility and reproducibility, not clinical effectiveness; prospective, governance-approved external validation is required before patient-level interpretation or deployment.
