# Interpretable AI plus Handheld, Portable Retinal Photographs: A Low-Cost Glaucoma Screening Solution for West Africa

arXiv: https://arxiv.org/abs/2609.25697 · HTML: https://mlsanity.com/paper/2609.25697/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 2 of its 44 references that are in the map.
- First posted on arXiv 22 Sep 2026.

## Builds on (most cited first, 2 of 2)

- [Grad-CAM: Visual Explanations from Deep Networks via Gradient-based Localization](https://mlsanity.com/paper/1610.02391/) (2016)
- [A Unified Approach to Interpreting Model Predictions](https://mlsanity.com/paper/1705.07874/) (2017)

## Abstract (arXiv)

Purpose: To develop and evaluate an interpretable artificial intelligence (AI) framework for glaucoma screening from low-cost portable, handheld retinal fundus photographs in a West African population and to compare its performance with clinical tabletop fundus imaging. Methods: We used data from a community-based study of 681 participants (1,362 eyes) in Nigeria, comprising 414 glaucoma, 478 glaucoma suspect, and 470 non-glaucoma eyes. Fundus photographs were acquired using the low-cost handheld, portable Volk Viva retinal camera and the Canon CR-2-AF tabletop camera. We fine-tuned component models separately to each device to perform vessel segmentation, cup and disc boundary segmentation, and feature extraction to detect optic nerve head features. A final classification model combined these components to classify scans as glaucoma, glaucoma suspect or non-glaucoma. Feature-weight analysis and Gradient-weighted Class Activation Mapping were used for interpretation. Results: The models performed well on both Volk Viva and Canon CR-2-AF images: Vessel segmentation: 0.98 Dice Coefficient (DC) (Volk) and 0.94 DC (Canon); Cup and disc segmentation: 0.95 DC (Volk) and 0.96 DC (Canon); Optic nerve head feature detection: area under the receiver operating characteristic curve (AUCs) of 0.83±0.03 (Volk) and 0.87±0.04 (Canon); Classification model: AUCs of 0.85±0.01 (Volk) and 0.93±0.01 (Canon). Reports for each image, present model decision confidence scores and decision-rationale visualizations to support clinical interpretation. Conclusions: Volk Viva results were reasonably comparable to Canon CR-2-AF in the component models and not far behind in classification. This shows that interpretable AI combined with low-cost, portable imaging may enhance community-level glaucoma screening, especially in settings with limited specialist access and resources.
