# Real-Time Musculoskeletal Surrogates for Pediatric Cerebral Palsy: a Credibility Pilot

arXiv: https://arxiv.org/abs/2608.28371 · HTML: https://mlsanity.com/paper/2608.28371/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 4 of its 14 references that are in the map.
- First posted on arXiv 28 Aug 2026.

## Builds on (most cited first, 4 of 4)

- [Simple and Scalable Predictive Uncertainty Estimation using Deep Ensembles](https://mlsanity.com/paper/1612.01474/) (2016)
- [An Empirical Evaluation of Generic Convolutional and Recurrent Networks for Sequence Modeling](https://mlsanity.com/paper/1803.01271/) (2018)
- [Physics-informed Deep Learning for Musculoskeletal Modelling: Predicting Muscle Forces and Joint Kinematics from Surface EMG](https://mlsanity.com/paper/2207.01435/) (2022)
- [Boosting Personalised Musculoskeletal Modelling with Physics-informed Knowledge Transfer](https://mlsanity.com/paper/2211.12315/) (2022)

## Abstract (arXiv)

Real-time musculoskeletal (MSK) surrogates could support personalized rehabilitation for children with cerebral palsy (CP), but their credibility depends on subject-wise evaluation, low inference latency, and calibrated uncertainty. We develop a subject-conditioned causal neural surrogate using OpenSim-derived static parameters, temporal joint kinematics, true muscle capacities, and training-only perturbations. On a real pediatric CP gait dataset comprising nine children, we use leave-one-subject-out validation on six development subjects and evaluate a frozen configuration once on three locked test subjects. The surrogate accurately reproduces musculotendon lengths (R-square = 0.92 in development validation and approximately 0.95 on locked subjects; nRMSE < 8%) while requiring only sub-millisecond to few-millisecond neural inference, well below a 100 ms interactive-rehabilitation target. In contrast, direct muscle-force estimation remains unstable at this small, heterogeneous scale: pooled metrics can overstate within-subject, per-muscle accuracy. A Monte Carlo credibility pilot further shows that propagating only +/-5% anthropometry and muscle-capacity variation produces severely overconfident nominal 90% intervals (approximately 4% force coverage and below 1% MT-length coverage). These results establish a leakage-free evaluation and credibility framework for pediatric MSK surrogates, while identifying force modeling and epistemic uncertainty as the central next challenges for clinically credible digital twins.
