# MAMA-FLUX.2: Image-to-Image Synthesis of Post-Contrast Breast DCE-MRI for the MAMA-SYNTH Challenge

arXiv: https://arxiv.org/abs/2608.25648 · HTML: https://mlsanity.com/paper/2608.25648/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Placed in Medical imaging and segmentation, one of 14 directions in Diffusion models.
- Builds on 5 of its 8 references that are in the map.
- First posted on arXiv 26 Aug 2026.

## Placed in

- Diffusion models / [Medical imaging and segmentation](https://mlsanity.com/diffusion/medical-imaging-and-segmentation/)

## Builds on (most cited first, 5 of 5)

- [High-Resolution Image Synthesis with Latent Diffusion Models](https://mlsanity.com/paper/2112.10752/) (2021)
- [Flow Matching for Generative Modeling](https://mlsanity.com/paper/2210.02747/) (2022)
- [Scaling Rectified Flow Transformers for High-Resolution Image Synthesis](https://mlsanity.com/paper/2403.03206/) (2024)
- [Flow Straight and Fast: Learning to Generate and Transfer Data with Rectified Flow](https://mlsanity.com/paper/2209.03003/) (2022)
- [A large-scale multicenter breast cancer DCE-MRI benchmark dataset with expert segmentations](https://mlsanity.com/paper/2406.13844/) (2024)

## Abstract (arXiv)

Dynamic contrast-enhanced breast MRI is central to cancer diagnosis and monitoring, but requires gadolinium-based contrast agents. In this work, we address pre-to-post contrast breast MRI synthesis for the MAMA-SYNTH challenge. We propose MAMA-FLUX.2, a conditional latent flow-matching approach based on FLUX.2-Klein-4B. The pre-contrast image is encoded as spatial conditioning, while the model predicts the flow field associated with the post-contrast target latent. To adapt the pretrained model efficiently, we use LoRA fine-tuning and introduce a regional training objective combining global flow matching, tumor-region supervision, and stable foreground regularization. We further investigate LoRA rank, intensity windowing, and regional loss weights on axial slices, prioritizing clinically relevant tumor-focused metrics. Our ablation study shows that moderate tumor and stable-foreground weighting improves the trade-off between image fidelity and tumor-region accuracy. The final model achieves the best overall balance with LoRA rank/α=64/64, MHAmax=25, λtumor=0.25, and λstable=0.1. These results demonstrate that compact pretrained rectified-flow transformers can be adapted for contrast-enhanced MRI synthesis using parameter-efficient fine-tuning and task-aware regional losses.
