# Change Point--Aware Evaluation and Re-Calibration of PPG-Based Blood Pressure Estimation

arXiv: https://arxiv.org/abs/2608.18639 · HTML: https://mlsanity.com/paper/2608.18639/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 9 of its 34 references that are in the map.
- First posted on arXiv 19 Aug 2026.

## Builds on (most cited first, 9 of 9)

- [A Simple Framework for Contrastive Learning of Visual Representations](https://mlsanity.com/paper/2002.05709/) (2020)
- [Supervised Contrastive Learning](https://mlsanity.com/paper/2004.11362/) (2020)
- [InceptionTime: Finding AlexNet for Time Series Classification](https://mlsanity.com/paper/1909.04939/) (2019)
- [PaPaGei: Open Foundation Models for Optical Physiological Signals](https://mlsanity.com/paper/2410.20542/) (2024)
- [An Evaluation of Change Point Detection Algorithms](https://mlsanity.com/paper/2003.06222/) (2020)
- [Pulse-PPG: An Open-Source Field-Trained PPG Foundation Model for Wearable Applications Across Lab and Field Settings](https://mlsanity.com/paper/2502.01108/) (2025)
- [AnyPPG: An ECG-Guided PPG Foundation Model Trained on Over 100,000 Hours of Recordings for Holistic Health Profiling](https://mlsanity.com/paper/2511.01747/) (2025)
- [Generalizable deep learning for photoplethysmography-based blood pressure estimation -- A Benchmarking Study](https://mlsanity.com/paper/2502.19167/) (2025)
- [Using Photoplethysmography to Detect Real-time Blood Pressure Changes with a Calibration-free Deep Learning Model](https://mlsanity.com/paper/2407.03274/) (2024)

## Abstract (arXiv)

Non-invasive continuous blood pressure (BP) monitoring using photoplethysmography (PPG) is a promising alternative to cuff-based measurements. However, existing PPG-based BP estimation studies predominantly rely on aggregated performance metrics (e.g., mean absolute error) computed over entire evaluation intervals, which can obscure model failures during rapid BP fluctuations and limit clinical relevance. In this work, we propose a fluctuation-aware evaluation framework for PPG-based BP estimation based on time-series change point detection. Instead of heuristic BP thresholding (e.g., DeltaBP > 10mmHg), we identify BP change points by capturing abrupt distributional shifts in BP trajectories and evaluate estimation performance specifically during these fluctuation periods. Our analysis shows that several state-of-the-art models exhibit substantial performance degradation around BP change points, and that periodic test-time calibration is insufficient to handle such dynamic BP variations. To address this limitation, we introduce a targeted re-calibration framework triggered by detected BP change points, improving robustness without modifying model architectures. To the best of our knowledge, this is the first systematic evaluation of PPG-based BP estimation from a BP change point perspective, highlighting the importance of fluctuation-aware evaluation and calibration for real-world continuous BP monitoring.
