# CUPA-T2*: Covariance-Aware Uncertainty Propagation and Alignment for T2* Mapping in Accelerated MRI

arXiv: https://arxiv.org/abs/2608.08693 · HTML: https://mlsanity.com/paper/2608.08693/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 9 of its 24 references that are in the map.
- First posted on arXiv 9 Aug 2026.

## Builds on (most cited first, 9 of 9)

- [Dropout as a Bayesian Approximation: Representing Model Uncertainty in Deep Learning](https://mlsanity.com/paper/1506.02142/) (2015)
- [What Uncertainties Do We Need in Bayesian Deep Learning for Computer Vision?](https://mlsanity.com/paper/1703.04977/) (2017)
- [Uncertainty Quantification in Deep MRI Reconstruction](https://mlsanity.com/paper/1901.11228/) (2019)
- [Uncertainty Estimation and Propagation in Accelerated MRI Reconstruction](https://mlsanity.com/paper/2308.02631/) (2023)
- [Uncertainty Quantification in Deep Learning for Safer Neuroimage Enhancement](https://mlsanity.com/paper/1907.13418/) (2019)
- [PINQI: An End-to-End Physics-Informed Approach to Learned Quantitative MRI Reconstruction](https://mlsanity.com/paper/2306.11023/) (2023)
- [Propagation and Attribution of Uncertainty in Medical Imaging Pipelines](https://mlsanity.com/paper/2309.16831/) (2023)
- [PixCUE: Joint Uncertainty Estimation and Image Reconstruction in MRI using Deep Pixel Classification](https://mlsanity.com/paper/2303.00111/) (2023)
- [Guiding Quantitative MRI Reconstruction with Phase-wise Uncertainty](https://mlsanity.com/paper/2502.20877/) (2025)

## Abstract (arXiv)

Quantitative T2* maps have strong potential for biomarker discovery but are limited by long scan times, rendering them impractical in clinical settings. Significant acceleration can be achieved through undersampling in k-space combined with learning-based reconstruction. However, reconstruction artifacts and noise can propagate into downstream T2* fitting, degrading its accuracy. We introduce CUPA-T2*, a framework that explicitly propagates voxel-wise inter-echo uncertainty from stochastic Monte Carlo dropout reconstructions to downstream T2* fitting via covariance-aware sampling. T2* fitting is performed with a heteroscedastic MLP and a correlation-based regularizer that encourages alignment between predicted variance and reconstruction uncertainty. Experiments on accelerated brain MRI data show tissue-dependent behavior: CUPA-T2* achieves competitive overall T2* fitting performance and improves white-matter performance at higher accelerations. Compared with a heteroscedastic baseline, the proposed framework substantially increases alignment between reconstruction uncertainty and predicted T2* variance, while also revealing a trade-off with calibration (ECE) and selective prediction performance (AURC). CUPA-T2* enables reconstruction uncertainty-aware T2* fitting and delivers voxel-wise uncertainty maps to support the interpretation of quantitative T2* estimates.
