# Matrix-Free Photoacoustic Image Reconstruction via Sensor-Token Self-Attention

arXiv: https://arxiv.org/abs/2607.25576 · HTML: https://mlsanity.com/paper/2607.25576/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 5 of its 36 references that are in the map.
- First posted on arXiv 28 Jul 2026.

## Builds on (most cited first, 5 of 5)

- [Attention Is All You Need](https://mlsanity.com/paper/1706.03762/) (2017)
- [Delving Deep into Rectifiers: Surpassing Human-Level Performance on ImageNet Classification](https://mlsanity.com/paper/1502.01852/) (2015)
- [Deep Learning for Photoacoustic Tomography from Sparse Data](https://mlsanity.com/paper/1704.04587/) (2017)
- [Deep Algorithm Unrolling for Biomedical Imaging](https://mlsanity.com/paper/2108.06637/) (2021)
- [Model-corrected learned primal-dual models for fast limited-view photoacoustic tomography](https://mlsanity.com/paper/2304.01963/) (2023)

## Abstract (arXiv)

Photoacoustic tomography (PAT) combines the optical absorption contrast of biological tissue with the spatial resolution of ultrasound, yet recovering the initial pressure distribution from sparse-view sensor measurements remains an ill-posed inverse problem. Iterative compressive-sensing solvers and unrolled deep networks both retain a dependence on the system matrix at inference, which leaves real-time clinical reconstruction computationally expensive. This paper proposes the Sensor Attention Network (SAN), a Transformer-based architecture that treats the full time series of each sensor as a token and maps raw measurements directly to the reconstructed image without invoking the system matrix at inference. For training and benchmarking, an analytical k-space H-matrix is constructed and validated against the k-Wave pseudo-spectral solver under matched geometry, achieving a mean per-sensor Pearson correlation of 0.919 +/- 0.049, with k-space apodization and Gaussian temporal damping acting synergistically to reduce the energy-normalized mismatch by 49%. Trained with a vessel-weighted loss on 488 augmented samples and evaluated on 46 held-out samples against ISTA, split-Bregman total variation (SBTV), and learned ISTA (LISTA), SAN attains the highest mean SSIM (0.522) and PSNR (22.09 dB) and the lowest NMSE (0.233). Paired t-tests and Wilcoxon signed-rank tests confirm the superiority of SAN over LISTA on PSNR, NMSE, and Pearson correlation at p < 1e-8, and over ISTA and SBTV on all fidelity metrics. By bypassing the H-matrix at inference, SAN reduces reconstruction time by at least an order of magnitude, supporting real-time PAT reconstruction.
