# Unsupervised Metal Artifact Reduction in Dental CBCT using Fine-tuned Cycle-Consistent Adversarial Networks

arXiv: https://arxiv.org/abs/2607.20977 · HTML: https://mlsanity.com/paper/2607.20977/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 6 of its 29 references that are in the map.
- First posted on arXiv 23 Jul 2026.

## Builds on (most cited first, 6 of 6)

- [Denoising Diffusion Probabilistic Models](https://mlsanity.com/paper/2006.11239/) (2020)
- [Generative Adversarial Network in Medical Imaging: A Review](https://mlsanity.com/paper/1809.07294/) (2018)
- [Real-time Cardiovascular MR with Spatio-temporal Artifact Suppression using Deep Learning - Proof of Concept in Congenital Heart Disease](https://mlsanity.com/paper/1803.05192/) (2018)
- [Artifact Reduction in 3D and 4D Cone-beam Computed Tomography Images with Deep Learning -- A Review](https://mlsanity.com/paper/2403.18565/) (2024)
- [MARformer: An Efficient Metal Artifact Reduction Transformer for Dental CBCT Images](https://mlsanity.com/paper/2311.09590/) (2023)
- [Multi-Channel Feature Extraction for Virtual Histological Staining of Photon Absorption Remote Sensing Images](https://mlsanity.com/paper/2307.01824/) (2023)

## Abstract (arXiv)

Metal artifacts generated by dental implants significantly degrade cone-beam computed tomography (CBCT) volumes, obscuring critical anatomical structures and compromising diagnostic precision. To address this, an unsupervised deep learning framework has been proposed for Metal Artifact Reduction (MAR) utilizing a Cycle-Consistent Adversarial Network (CycleGAN) optimized for high-fidelity restoration. Unlike supervised methods that rely on unattainable voxel-aligned paired datasets, the proposed approach leverages an unpaired dataset of approximately 4,000 images, curated from the public ToothFairy dataset. The architecture integrates U-Net-based generators and PatchGAN discriminators, specifically tuned to mitigate generative hallucinations and preserve morphological integrity. Quantitative benchmarking on a held-out test set demonstrates a 34.6% improvement in the Blind/Referenceless Image Spatial Quality Evaluator (BRISQUE) score, a substantial reduction in Fr'echet Inception Distance (FID) from 207.03 to 157.04, and a superior Structural Similarity Index Measure (SSIM) of 0.9105. The framework achieves real-time efficiency with a 3.03 ms inference time per slice, effectively suppressing artifacts while preserving anatomical detail. Expert validation confirms high fidelity; however, to ensure reliability in extreme cases, the architecture is recommended as a clinical decision-support tool under human-in-the-loop oversight. By enhancing diagnostic clarity via a scalable software pipeline, this study provides a robust solution for high-fidelity dental implant imaging.
