# Prospective clinical indication, post-hoc report leakage, and fusion design in multi-image chest radiograph classification: a patient-clustered evaluation

arXiv: https://arxiv.org/abs/2607.13800 · HTML: https://mlsanity.com/paper/2607.13800/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 10 of its 16 references that are in the map.
- First posted on arXiv 15 Jul 2026.

## Builds on (most cited first, 10 of 10)

- [Densely Connected Convolutional Networks](https://mlsanity.com/paper/1608.06993/) (2016)
- [On Calibration of Modern Neural Networks](https://mlsanity.com/paper/1706.04599/) (2017)
- [Deep Sets](https://mlsanity.com/paper/1703.06114/) (2017)
- [Publicly Available Clinical BERT Embeddings](https://mlsanity.com/paper/1904.03323/) (2019)
- [Contrastive Learning of Medical Visual Representations from Paired Images and Text](https://mlsanity.com/paper/2010.00747/) (2020)
- [Making the Most of Text Semantics to Improve Biomedical Vision--Language Processing](https://mlsanity.com/paper/2204.09817/) (2022)
- [CheXbert: Combining Automatic Labelers and Expert Annotations for Accurate Radiology Report Labeling Using BERT](https://mlsanity.com/paper/2004.09167/) (2020)
- [Gated Multimodal Units for Information Fusion](https://mlsanity.com/paper/1702.01992/) (2017)
- [VisualCheXbert: Addressing the Discrepancy Between Radiology Report Labels and Image Labels](https://mlsanity.com/paper/2102.11467/) (2021)
- [ReXGradient-160K: A Large-Scale Publicly Available Dataset of Chest Radiographs with Free-text Reports](https://mlsanity.com/paper/2505.00228/) (2025)

## Abstract (arXiv)

Chest radiograph datasets often combine multiple images with Clinical Indication, Findings, and Impression, although these inputs are produced at different stages of care. We evaluated 15,000 ReXGradient-160K studies with two readable images and five CheXbert-derived report observations. Frozen DenseNet-121 and Bio+ClinicalBERT encoders were used to compare image-only, Indication-only, fixed-order multimodal, random-swap, DeepSets, and SectionGuard-MI models. Findings and Impression were evaluated only as post-hoc leakage controls. Models were trained with five seeds, and public-test uncertainty was estimated with 2,000 patient-cluster bootstrap replicates. Under U-Ones, macro AUROC was 0.643 for the primary image, 0.694 for two images, 0.749 for Indication, and 0.780 for ordinary two-image-plus-Indication fusion. SectionGuard-MI achieved AUROC 0.783 and AUPRC 0.260. Relative to ordinary fusion, its paired AUROC difference was 0.0031 (95% CI, -0.0042 to 0.0104; adjusted p=0.374), while its AUPRC difference was 0.0289 (95% CI, 0.0095 to 0.0413; adjusted p=0.004). DeepSets had the highest prospective AUROC point estimate (0.787), and random-swap fusion had the highest prospective AUPRC point estimate (0.265) with better calibration than SectionGuard-MI. Full report text alone reached AUROC 0.979 and AUPRC 0.836; AUROC remained above 0.973 after exact or expanded masking. These results show that prospective Indication is strongly associated with report-derived targets, permutation-aware fusion is competitive, and post-hoc report text creates substantial report-label circularity.
