# Privacy-Preserving Industrial Ergonomics: mmWave-Based Automated REBA Scoring and Pose Estimation

arXiv: https://arxiv.org/abs/2607.02611 · HTML: https://mlsanity.com/paper/2607.02611/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 8 of its 21 references that are in the map.
- First posted on arXiv 1 Jul 2026.

## Builds on (most cited first, 8 of 8)

- [PointNet: Deep Learning on Point Sets for 3D Classification and Segmentation](https://mlsanity.com/paper/1612.00593/) (2016)
- [PointNet++: Deep Hierarchical Feature Learning on Point Sets in a Metric Space](https://mlsanity.com/paper/1706.02413/) (2017)
- [MM-Fi: Multi-Modal Non-Intrusive 4D Human Dataset for Versatile Wireless Sensing](https://mlsanity.com/paper/2305.10345/) (2023)
- [mm-Pose: Real-Time Human Skeletal Posture Estimation using mmWave Radars and CNNs](https://mlsanity.com/paper/1911.09592/) (2019)
- [HuPR: A Benchmark for Human Pose Estimation Using Millimeter Wave Radar](https://mlsanity.com/paper/2210.12564/) (2022)
- [Fast and Scalable Human Pose Estimation using mmWave Point Cloud](https://mlsanity.com/paper/2205.00097/) (2022)
- [RT-Pose: A 4D Radar Tensor-based 3D Human Pose Estimation and Localization Benchmark](https://mlsanity.com/paper/2407.13930/) (2024)
- [Action Recognition in Real-World Ambient Assisted Living Environment](https://mlsanity.com/paper/2503.23214/) (2025)

## Abstract (arXiv)

Work-related Musculoskeletal Disorders (WMSDs) require continuous ergonomic assessments. While Rapid Entire Body Assessment (REBA) is a gold-standard observation tool, manual monitoring is labor-intensive, and vision-based automation leads to privacy concerns. This paper proposes a novel end-to-end multi-task learning framework for privacy-preserving ergonomic assessment using millimetre-wave (mmWave) radar. A spatio-temporal backbone reconstructs 3D human skeletons, which serves as the biomechanical foundation for a subsequent regression head to generate REBA risk scores. To overcome the sparsity of radar point clouds, we utilise a multi-objective loss function incorporating biomechanical limits and temporal smoothness constraints. Furthermore, we implement an oversampling strategy to address the imbalance of high-risk postures in existing datasets. Experimental results on MMFi dataset demonstrate that our framework achieves a Categorical Accuracy of 77.78% and real-time performance with an inference latency of 5.70 ms. Our method reaches a High-risk REBA MAE of 0.93, which significantly outperforms both direct regression and two-stage pipelines in high-risk scenarios, providing a robust solution for non-invasive industrial ergonomic assessment.