# RadiomicNet: A Hybrid Radiomics-Guided Lightweight Architecture for Interpretable Medical Image Segmentation

arXiv: https://arxiv.org/abs/2607.02185 · HTML: https://mlsanity.com/paper/2607.02185/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 7 of its 14 references that are in the map.
- First posted on arXiv 2 Jul 2026.

## Builds on (most cited first, 7 of 7)

- [U-Net: Convolutional Networks for Biomedical Image Segmentation](https://mlsanity.com/paper/1505.04597/) (2015)
- [MobileNetV2: Inverted Residuals and Linear Bottlenecks](https://mlsanity.com/paper/1801.04381/) (2018)
- [UNet++: A Nested U-Net Architecture for Medical Image Segmentation](https://mlsanity.com/paper/1807.10165/) (2018)
- [KAN: Kolmogorov-Arnold Networks](https://mlsanity.com/paper/2404.19756/) (2024)
- [Kvasir-SEG: A Segmented Polyp Dataset](https://mlsanity.com/paper/1911.07069/) (2019)
- [U-KAN Makes Strong Backbone for Medical Image Segmentation and Generation](https://mlsanity.com/paper/2406.02918/) (2024)
- [Focus on Texture: Rethinking Pre-training in Masked Autoencoders for Medical Image Classification](https://mlsanity.com/paper/2507.10869/) (2025)

## Abstract (arXiv)

Deep learning has achieved remarkable performance in medical image segmentation, yet it suffers from critical limitations: mathematical intractability, substantial parameter requirements, and lack of clinical interpretability. We propose RadiomicNet, a novel two-stream hybrid architecture that enhances standard deep learning by integrating handcrafted radiomics features directly into the segmentation learning process. The key contribution is the Radiomics Attention Gate (RAG), which leverages Gray-Level Co-occurrence Matrix (GLCM) and Local Binary Pattern (LBP) features to modulate skip-connection attention in a lightweight MobileNetV2-based encoder-decoder, providing ante-hoc interpretability without post-hoc approximations. A novel Radiomics Consistency Loss further enforces alignment between texture complexity and prediction uncertainty, reducing Expected Calibration Error (ECE) from 0.142 to 0.118. RadiomicNet achieves a Dice Similarity Coefficient (DSC) of 0.763 +/- 0.231 on the Breast Ultrasound Images (BUSI) dataset and 0.854 +/- 0.112 on Kvasir-SEG, outperforming U-KAN by 1.2% and 1.8%, respectively (p < 0.05, Wilcoxon signed-rank test), with only 3.27M parameters, 9.5x fewer than standard U-Net and 4.3x fewer than U-KAN. Gradient-based feature importance analysis reveals that GLCM dissimilarity (15.24%), GLCM energy (14.56%), and LBP entropy (11.49%) are the dominant radiomics cues, providing clinically meaningful explanations for segmentation decisions. The proposed approach demonstrates that compact, interpretable models grounded in domain knowledge can deliver state-of-the-art segmentation performance with substantially reduced computational overhead.
