# Bistable by Construction: Wall-Clock-Calibrated State Monitors Have No Moment-Detection Regime at Agent Cadence

arXiv: https://arxiv.org/abs/2606.19386 · HTML: https://mlsanity.com/paper/2606.19386/

## Key facts

- Cited by 1 papers in the map (data through 14 Oct 2026).
- Builds on 5 of its 11 references that are in the map.
- First posted on arXiv 15 Jun 2026.

## Builds on (most cited first, 5 of 5)

- [AgentHarm: A Benchmark for Measuring Harmfulness of LLM Agents](https://mlsanity.com/paper/2410.09024/) (2024)
- [AgentSpec: Customizable Runtime Enforcement for Safe and Reliable LLM Agents](https://mlsanity.com/paper/2503.18666/) (2025)
- [The 'Problem' of Human Label Variation: On Ground Truth in Data, Modeling and Evaluation](https://mlsanity.com/paper/2211.02570/) (2022)
- [ProbGuard: Proactive Runtime Monitoring for LLM Agent Safety via Probabilistic Prediction](https://mlsanity.com/paper/2508.00500/) (2025)
- [The Saturation Trap and the Subjectivity of Intervention Timing: Why Affect-Based Triggers and LLM Judges Fail to Time Interventions on Autonomous Agents](https://mlsanity.com/paper/2606.04296/) (2026)

## Built on by (most cited first, 1 of 1)

- [Epi-Logic: A Conceptual Framework for Epistemic Runtime Control, Schema Validity Checking, and Controlled Accommodation in Autonomous AI Agents](https://mlsanity.com/paper/2609.24755/) (2026)

## Abstract (arXiv)

Runtime monitors for autonomous agents commonly threshold an accumulated internal state - a behavioural baseline, a drift statistic, or, in our prior work, a modelled affective state. We previously reported a State Saturation Trap: threshold-on-state triggers over a continuous affect engine become near-constant alarms on SWE-bench debugging agents (Modgil 2026). A post-release audit found the engine received dt=0 between actions, so its exponential decay never operated: the published trap is a pure-accumulator result. We correct the record (erratum, v2) and treat the flaw as an experiment. The key variable it exposes is whether a monitor's dynamics are calibrated in sample time (per observation, as in CUSUM) or wall-clock time (half-lives in seconds, as in affect models and EMA baselines). On fixed-rate streams these coincide; on agent streams, where inter-action time varies by orders of magnitude, they do not. A pre-registered sweep over uniform intervals (dt in {0..600}s) on 20 trajectories shows the wall-clock level trigger has two regimes: at dt<=1s a constant alarm (20/20; median 18 firings); at dt>=60s silent. Every critical dt lies in (1,30]s. A scriptable gpt-5.4-mini agent loop measures latency at median 1.53s (p90 2.33s), inside the trap regime, vindicating the empirical finding under a corrected mechanism. The structure is a property of the calibration class, not the engine: a minimal wall-clock accumulator over the raw error stream reproduces the same cliff, while a sample-time CUSUM over the identical stream is exactly dt-invariant (20/20). A rising-edge trigger with hysteresis fires 0-3 times per trajectory in every condition. We conclude that wall-clock-calibrated leaky-integrator monitors admit no regime in which they act as moment detectors on agent streams; transition detection escapes the trap at every cadence, but does not recover human intervention timing.
