# GLINT: Sparsely Gated Vision-Language Alignment for Fine-Grained Radiology Representations

arXiv: https://arxiv.org/abs/2606.03180 · HTML: https://mlsanity.com/paper/2606.03180/

## Key facts

- Cited by 2 papers in the map (data through 14 Oct 2026).
- Placed in Medical vision-language models, one of 16 directions in Multimodal LLMs / vision-language models.
- Builds on 13 of its 76 references that are in the map.
- First posted on arXiv 2 Jun 2026.

## Placed in

- Multimodal LLMs / vision-language models / [Medical vision-language models](https://mlsanity.com/mllm/medical-vision-language-models/)
- Mixture-of-experts / [Medical and biomedical MoE](https://mlsanity.com/moe/medical-and-biomedical-moe/)

## Builds on (most cited first, 13 of 13)

- [DINOv2: Learning Robust Visual Features without Supervision](https://mlsanity.com/paper/2304.07193/) (2023)
- [DINOv3](https://mlsanity.com/paper/2508.10104/) (2025)
- [gpt-oss-120b & gpt-oss-20b Model Card](https://mlsanity.com/paper/2508.10925/) (2025)
- [SigLIP 2: Multilingual Vision-Language Encoders with Improved Semantic Understanding, Localization, and Dense Features](https://mlsanity.com/paper/2502.14786/) (2025)
- [V-JEPA 2: Self-Supervised Video Models Enable Understanding, Prediction and Planning](https://mlsanity.com/paper/2506.09985/) (2025)
- [MONAI: An open-source framework for deep learning in healthcare](https://mlsanity.com/paper/2211.02701/) (2022)
- [MedGemma Technical Report](https://mlsanity.com/paper/2507.05201/) (2025)
- [V-JEPA 2.1: Unlocking Dense Features in Video Self-Supervised Learning](https://mlsanity.com/paper/2603.14482/) (2026)
- [Advancing Multimodal Medical Capabilities of Gemini](https://mlsanity.com/paper/2405.03162/) (2024)
- [Visual Representation Alignment for Multimodal Large Language Models](https://mlsanity.com/paper/2509.07979/) (2025)
- [ChestX-Det10: Chest X-ray Dataset on Detection of Thoracic Abnormalities](https://mlsanity.com/paper/2006.10550/) (2020)
- [Comprehensive language-image pre-training for 3D medical image understanding](https://mlsanity.com/paper/2510.15042/) (2025)
- [ReXGroundingCT: A 3D Chest CT Dataset for Segmentation of Findings from Free-Text Reports](https://mlsanity.com/paper/2507.22030/) (2025)

## Built on by (most cited first, 2 of 2)

- [Volumetric Radiology AI in the Era of Multimodal Large Language Models](https://mlsanity.com/paper/2608.20549/) (2026)
- [SentZero: An Enhanced Sentence-Centric Vision-Language Pretraining for Multi-Task Zero-Shot Chest X-Ray Analysis](https://mlsanity.com/paper/2609.34479/) (2026)

## Abstract (arXiv)

Vision-language models (VLMs) for radiology have emerged as a scalable paradigm by leveraging image-report pairs naturally produced in clinical workflows. However, this pairing reveals a mismatch in scale: each finding occupies only a small region of the image, yet supervision is provided only at the global image-report level. This poses a central challenge: prior approaches spread weight densely across all patches rather than concentrating on the sparse subset relevant to a given query. To address this, we present GLINT (Gated Language-Image alignmeNT), a framework that explicitly models this sparse correspondence. On the alignment side, we introduce Sparsely Gated Alignment, a novel architecture in which a sigmoid gate over a separate gate embedding space activates only the patches relevant to each textual query, enforcing explicit sparsity. On the representation side, we add Dense Feature Regularization, which anchors the trainable encoder's intermediate features to a frozen self-supervised learning (SSL) teacher, preserving the fine-grained patch features that the gate relies on. The same recipe applies to both 2D chest X-ray (CXR) and 3D chest computed tomography (CT), built with DINOv3 and V-JEPA 2.1, respectively. GLINT enables zero-shot classification, grounding, and segmentation from free-text queries, and to our knowledge is the first to demonstrate zero-shot segmentation on 3D CT volumes without mask supervision. Notably, the most pronounced gains arise on zero-shot grounding and segmentation, where sparse, query-specific localization is required, consistent with our design intent. In downstream evaluation, GLINT outperforms both SSL encoders and medical VLMs on classification, report generation, and segmentation.
