# Multi-Contrast MRI Motion Correction via Parameter-Informed Disentanglement and Adaptive Experts

arXiv: https://arxiv.org/abs/2606.00146 · HTML: https://mlsanity.com/paper/2606.00146/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 13 of its 37 references that are in the map.
- First posted on arXiv 29 May 2026.

## Builds on (most cited first, 13 of 13)

- [Learning Transferable Visual Models From Natural Language Supervision](https://mlsanity.com/paper/2103.00020/) (2021)
- [Denoising Diffusion Probabilistic Models](https://mlsanity.com/paper/2006.11239/) (2020)
- [High-Resolution Image Synthesis with Latent Diffusion Models](https://mlsanity.com/paper/2112.10752/) (2021)
- [Swin Transformer: Hierarchical Vision Transformer using Shifted Windows](https://mlsanity.com/paper/2103.14030/) (2021)
- [SwinIR: Image Restoration Using Swin Transformer](https://mlsanity.com/paper/2108.10257/) (2021)
- [Restormer: Efficient Transformer for High-Resolution Image Restoration](https://mlsanity.com/paper/2111.09881/) (2021)
- [Beyond a Gaussian Denoiser: Residual Learning of Deep CNN for Image Denoising](https://mlsanity.com/paper/1608.03981/) (2016)
- [Simple Baselines for Image Restoration](https://mlsanity.com/paper/2204.04676/) (2022)
- [The RSNA-ASNR-MICCAI BraTS 2021 Benchmark on Brain Tumor Segmentation and Radiogenomic Classification](https://mlsanity.com/paper/2107.02314/) (2021)
- [ResShift: Efficient Diffusion Model for Image Super-resolution by Residual Shifting](https://mlsanity.com/paper/2307.12348/) (2023)
- [Measurement-conditioned Denoising Diffusion Probabilistic Model for Under-sampled Medical Image Reconstruction](https://mlsanity.com/paper/2203.03623/) (2022)
- [All-In-One Medical Image Restoration via Task-Adaptive Routing](https://mlsanity.com/paper/2405.19769/) (2024)
- [Annealed Score-Based Diffusion Model for MR Motion Artifact Reduction](https://mlsanity.com/paper/2301.03027/) (2023)

## Abstract (arXiv)

Motion artifacts in magnetic resonance imaging (MRI) degrade diagnostic reliability. Existing deep learning methods are typically contrast-specific and fail to generalize across diverse modalities and artifact severities. We propose a unified framework combining parameter-informed contrast disentanglement with severity-aware adaptive correction. ScanCLIP, pretrained on over 30,000 MRI text-image pairs, derives contrast embeddings from acquisition parameters to disentangle contrast style from anatomical content, yielding contrast-free features. A Vision Transformer then estimates motion severity and routes features through a Mixture-of-Experts network, enabling targeted artifact correction. A dual-pathway decoder reconstructs both the clean image and residual artifact map, enforcing image-space consistency. On IXI and HCP benchmarks, our method improves PSNR by 0.75 dB and SSIM by up to 0.0279 over state-of-the-art approaches, with larger gains at higher artifact severities. It further demonstrates robust zero-shot generalization on real-world clinical data acquired with unseen scanning parameters, where existing methods either fail to remove artifacts or introduce additional distortions.
