# A Statistical Multi-Objective Framework for Assessing Sensitivity of Radiomic AI Models to Acquisition Parameters

arXiv: https://arxiv.org/abs/2605.14667 · HTML: https://mlsanity.com/paper/2605.14667/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 7 of its 30 references that are in the map.
- First posted on arXiv 14 May 2026.

## Builds on (most cited first, 7 of 7)

- [Deep Residual Learning for Image Recognition](https://mlsanity.com/paper/1512.03385/) (2015)
- [Very Deep Convolutional Networks for Large-Scale Image Recognition](https://mlsanity.com/paper/1409.1556/) (2014)
- [EfficientNet: Rethinking Model Scaling for Convolutional Neural Networks](https://mlsanity.com/paper/1905.11946/) (2019)
- [MobileNetV2: Inverted Residuals and Linear Bottlenecks](https://mlsanity.com/paper/1801.04381/) (2018)
- [Visual Transformers: Token-based Image Representation and Processing for Computer Vision](https://mlsanity.com/paper/2006.03677/) (2020)
- [Validation, comparison, and combination of algorithms for automatic detection of pulmonary nodules in computed tomography images: the LUNA16 challenge](https://mlsanity.com/paper/1612.08012/) (2016)
- [Distilling foundation models for robust and efficient models in digital pathology](https://mlsanity.com/paper/2501.16239/) (2025)

## Abstract (arXiv)

A main barrier for the deployment of AI radiomic systems in clinical routine is their drop in performance under heterogeneous multicentre acquisition protocols. This work presents a performance-oriented framework for quantifying scan parameter sensitivity of radiomic AI models, while identifying clinically significant parameter regions associated with improved cross-dataset robustness. Mixed-effects modelling in combination with a hierarchical Pareto-based strategy is used to quantify the influence of acquisition parameters and select critical values associated to low performance of predictive models. We apply our framework to lung cancer diagnosis in CT scans using two independent multicentre datasets (a public dataset and own-collected private data) and several state-of-the-art architectures. To evaluate transferability of results, CT parameters were selected using the private data and validated on the public set. With the selected configurations, validation in low performance conditions has 0.72 ([0.59,0.86], 95% CI) accuracy and 0.71 ([0.58, 0. 84], 95% CI) F1Score, while in high performance ones, we obtain 0.88 ([0.7, 1.0], 95% CI) accuracy with 0.87 ([0.69, 1.0], 95% CI) F1Score.
