# A Paired Point-of-Care Ultrasound Dataset for Image Quality Enhancement and Benchmarking via a cGAN Baseline

arXiv: https://arxiv.org/abs/2605.08282 · HTML: https://mlsanity.com/paper/2605.08282/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 8 of its 53 references that are in the map.
- First posted on arXiv 8 May 2026.

## Builds on (most cited first, 8 of 8)

- [U-Net: Convolutional Networks for Biomedical Image Segmentation](https://mlsanity.com/paper/1505.04597/) (2015)
- [Generative Adversarial Networks](https://mlsanity.com/paper/2203.00667/) (2022)
- [Image-to-Image Translation with Conditional Adversarial Networks](https://mlsanity.com/paper/1611.07004/) (2016)
- [Which Training Methods for GANs do actually Converge?](https://mlsanity.com/paper/1801.04406/) (2018)
- [NIPS 2016 Tutorial: Generative Adversarial Networks](https://mlsanity.com/paper/1701.00160/) (2016)
- [A New Dataset and A Baseline Model for Breast Lesion Detection in Ultrasound Videos](https://mlsanity.com/paper/2207.00141/) (2022)
- [A Review on Deep Learning in Medical Image Reconstruction](https://mlsanity.com/paper/1906.10643/) (2019)
- [Automatic Prostate Volume Estimation in Transabdominal Ultrasound Images](https://mlsanity.com/paper/2502.07859/) (2025)

## Abstract (arXiv)

Purpose: We aim to enhance the image quality of point-of-care ultrasound (POCUS) devices using deep learning and a novel paired dataset of POCUS and high-end ultrasound images. Approach: We collected the first accurately paired dataset using a custom-built automated gantry system of low-end POCUS and high-end ultrasound images. A conditional generative adversarial network (cGAN) was utilized based on the pix2pix architecture, with a U-Net generator that incorporates both L1 and structural similarity index (SSIM) losses to improve perceptual quality. Pretraining on a simulation dataset further boosts performance. Evaluation was performed on 1064 paired ex vivo tissue and phantom ultrasound image sets. Results: Our approach improves the SSIM from 0.29 to 0.54 and PSNR from 19.16 dB to 22.41 dB. No-reference metrics also indicate substantial enhancement, with the Natural Image Quality Evaluator (NIQE) and Perception-based Image Quality Evaluator (PIQE) scores dropping from 7.95 to 4.44 and 31.12 to 19.99, respectively. Conclusions: This work presents the first publicly available accurately paired dataset of low-end POCUS to high end ultrasound images. Additionally, our results demonstrate the potential of the proposed framework to overcome hardware limitations of handheld POCUS, enhancing its diagnostic value in low-resource and point-of-care settings. The POCUS-IQ Dataset is publicly available at https://github.com/NKI-MedTech-AI/POCUS-IQ.