# AnemiaVision: Non-Invasive Anemia Detection via Smartphone Imagery Using EfficientNet-B3 with TrivialAugmentWide, Mixup Augmentation, and Persistent Patient History Management

arXiv: https://arxiv.org/abs/2604.22964 · HTML: https://mlsanity.com/paper/2604.22964/

## Key facts

- Cited by 1 papers in the map (data through 14 Oct 2026).
- Builds on 6 of its 18 references that are in the map.
- First posted on arXiv 24 Apr 2026.

## Builds on (most cited first, 6 of 6)

- [Grad-CAM: Visual Explanations from Deep Networks via Gradient-based Localization](https://mlsanity.com/paper/1610.02391/) (2016)
- [EfficientNet: Rethinking Model Scaling for Convolutional Neural Networks](https://mlsanity.com/paper/1905.11946/) (2019)
- [mixup: Beyond Empirical Risk Minimization](https://mlsanity.com/paper/1710.09412/) (2017)
- [Gaussian Error Linear Units (GELUs)](https://mlsanity.com/paper/1606.08415/) (2016)
- [Random Erasing Data Augmentation](https://mlsanity.com/paper/1708.04896/) (2017)
- [TrivialAugment: Tuning-free Yet State-of-the-Art Data Augmentation](https://mlsanity.com/paper/2103.10158/) (2021)

## Built on by (most cited first, 1 of 1)

- [NeoJaundice-AI: Smartphone-Based Neonatal Jaundice Detection Using Dual-Input Deep Learning and Synthetic Augmentation](https://mlsanity.com/paper/2606.20689/) (2026)

## Abstract (arXiv)

Anemia affects over one billion people globally and remains severely under-diagnosed in low-resource regions where laboratory blood tests are inaccessible. This paper presents AnemiaVision, an end-to-end web-based system for non-invasive anemia screening from smartphone photographs of the palpebral conjunctiva and fingernail beds. The proposed pipeline fine-tunes a pre-trained EfficientNet-B3 backbone with a redesigned three-layer classifier head incorporating BatchNorm, GELU activations, and high-rate Dropout (0.45/0.35). Training employs four orthogonal accuracy-boosting techniques: TrivialAugmentWide for policy-free image augmentation, RandomErasing for spatial regularisation, Mixup (alpha=0.2) for inter-class smoothing, and cosine-annealing scheduling with linear warmup. Early stopping is governed by peak validation accuracy rather than validation loss to prevent premature termination on high-variance epochs. The deployed Flask application integrates persistent patient-history management backed by PostgreSQL on Render, with an automated database-migration entrypoint ensuring zero data loss across redeploys. Ablation experiments demonstrate that accuracy-first early stopping contributes +1.6% and Mixup contributes +2.8% to final validation accuracy. Overall, the proposed system achieves a validation accuracy of 96.2% and AUC-ROC of 0.98, compared with 44.9% validation accuracy and AUC-ROC of 0.58 from the three-epoch CPU-only baseline. Sensitivity for the anemic class reaches 0.96, making the system suitable as a first-line screening tool for community health workers in rural settings. The system is publicly accessible and source code is openly available.
