# Opportunistic Bone-Loss Screening from Routine Knee Radiographs Using a Multi-Task Deep Learning Framework with Sensitivity-Constrained Threshold Optimization

arXiv: https://arxiv.org/abs/2604.20268 · HTML: https://mlsanity.com/paper/2604.20268/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 7 of its 32 references that are in the map.
- First posted on arXiv 22 Apr 2026.

## Builds on (most cited first, 7 of 7)

- [Deep Residual Learning for Image Recognition](https://mlsanity.com/paper/1512.03385/) (2015)
- [PyTorch: An Imperative Style, High-Performance Deep Learning Library](https://mlsanity.com/paper/1912.01703/) (2019)
- [ImageNet Large Scale Visual Recognition Challenge](https://mlsanity.com/paper/1409.0575/) (2014)
- [Grad-CAM: Visual Explanations from Deep Networks via Gradient-based Localization](https://mlsanity.com/paper/1610.02391/) (2016)
- [A Survey on Deep Learning in Medical Image Analysis](https://mlsanity.com/paper/1702.05747/) (2017)
- [An Overview of Multi-Task Learning in Deep Neural Networks](https://mlsanity.com/paper/1706.05098/) (2017)
- [Automatic Knee Osteoarthritis Diagnosis from Plain Radiographs: A Deep Learning-Based Approach](https://mlsanity.com/paper/1710.10589/) (2017)

## Abstract (arXiv)

Background: Osteoporosis and osteopenia are often undiagnosed until fragility fractures occur. Dual-energy X-ray absorptiometry (DXA) is the reference standard for bone mineral density (BMD) assessment, but access remains limited. Knee radiographs are obtained at high volume for osteoarthritis evaluation and may offer an opportunity for opportunistic bone-loss screening. Objective: To develop and evaluate a multi-task deep learning system for opportunistic bone-loss screening from routine knee radiographs without additional imaging or patient visits. Methods: We developed STR-Net, a multi-task framework for single-channel grayscale knee radiographs. The model includes a shared backbone, global average pooling feature aggregation, a shared neck, and a task-aware representation routing module connected to three task-specific heads: binary screening (Normal vs. Bone Loss), severity sub-classification (Osteopenia vs. Osteoporosis), and weakly coupled T-score regression with optional clinical variables. A sensitivity-constrained threshold optimization strategy (minimum sensitivity >= 0.86) was applied. The dataset included 1,570 knee radiographs, split at the patient level into training (n=1,120), validation (n=226), and test (n=224) sets. Results: On the held-out test set, STR-Net achieved an AUROC of 0.933, sensitivity of 0.904, specificity of 0.773, and AUPRC of 0.956 for binary screening. Severity sub-classification achieved an AUROC of 0.898. The T-score regression branch showed a Pearson correlation of 0.801 with DXA-measured T-scores in a pilot subset (n=31), with MAE of 0.279 and RMSE of 0.347. Conclusions: STR-Net enables single-pass bone-loss screening, severity stratification, and quantitative T-score estimation from routine knee radiographs. Prospective clinical validation is needed before deployment.