# 4D Vessel Reconstruction for Benchtop Thrombectomy Analysis

arXiv: https://arxiv.org/abs/2604.06671 · HTML: https://mlsanity.com/paper/2604.06671/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 12 of its 43 references that are in the map.
- First posted on arXiv 8 Apr 2026.

## Builds on (most cited first, 12 of 12)

- [SAM 2: Segment Anything in Images and Videos](https://mlsanity.com/paper/2408.00714/) (2024)
- [4D Gaussian Splatting for Real-Time Dynamic Scene Rendering](https://mlsanity.com/paper/2310.08528/) (2023)
- [SuGaR: Surface-Aligned Gaussian Splatting for Efficient 3D Mesh Reconstruction and High-Quality Mesh Rendering](https://mlsanity.com/paper/2311.12775/) (2023)
- [Tracking Anything with Decoupled Video Segmentation](https://mlsanity.com/paper/2309.03903/) (2023)
- [Putting the Object Back into Video Object Segmentation](https://mlsanity.com/paper/2310.12982/) (2023)
- [SAMURAI: Adapting Segment Anything Model for Zero-Shot Visual Tracking with Motion-Aware Memory](https://mlsanity.com/paper/2411.11922/) (2024)
- [Dynamic Gaussians Mesh: Consistent Mesh Reconstruction from Dynamic Scenes](https://mlsanity.com/paper/2404.12379/) (2024)
- [DynaSurfGS: Dynamic Surface Reconstruction with Planar-based Gaussian Splatting](https://mlsanity.com/paper/2408.13972/) (2024)
- [GauSTAR: Gaussian Surface Tracking and Reconstruction](https://mlsanity.com/paper/2501.10283/) (2025)
- [MaGS: Reconstructing and Simulating Dynamic 3D Objects with Mesh-adsorbed Gaussian Splatting](https://mlsanity.com/paper/2406.01593/) (2024)
- [Temporally Coherent General Dynamic Scene Reconstruction](https://mlsanity.com/paper/1907.08195/) (2019)
- [SWiT-4D: Sliding-Window Transformer for Lossless and Parameter-Free Temporal 4D Generation](https://mlsanity.com/paper/2512.10860/) (2025)

## Abstract (arXiv)

Introduction: Mechanical thrombectomy can cause vessel deformation and procedure-related injury. Benchtop models are widely used for device testing, but time-resolved, full-field 3D vessel-motion measurements remain limited. Methods: We developed a nine-camera, low-cost multi-view workflow for benchtop thrombectomy in silicone middle cerebral artery phantoms (2160p, 20 fps). Multi-view videos were calibrated, segmented, and reconstructed with 4D Gaussian Splatting. Reconstructed point clouds were converted to fixed-connectivity edge graphs for region-of-interest (ROI) displacement tracking and a relative surface-based stress proxy. Stress-proxy values were derived from edge stretch using a Neo-Hookean mapping and reported as comparative surface metrics. A synthetic Blender pipeline with known deformation provided geometric and temporal validation. Results: In synthetic bulk translation, the stress proxy remained near zero for most edges (median ≈ 0 MPa; 90th percentile 0.028 MPa), with sparse outliers. In synthetic pulling (1-5 mm), reconstruction showed close geometric and temporal agreement with ground truth, with symmetric Chamfer distance of 1.714-1.815 mm and precision of 0.964-0.972 at τ = 1 mm. In preliminary benchtop comparative trials (one trial per condition), cervical aspiration catheter placement showed higher max-median ROI displacement and stress-proxy values than internal carotid artery terminus placement. Conclusion: The proposed protocol provides standardized, time-resolved surface kinematics and comparative relative displacement and stress proxy measurements for thrombectomy benchtop studies. The framework supports condition-to-condition comparisons and methods validation, while remaining distinct from absolute wall-stress estimation. Implementation code and example data are available at https://ethanuser.github.io/vessel4D