# Spatiotemporal Gaussian representation-based dynamic reconstruction and motion estimation framework for time-resolved volumetric MR imaging (DREME-GSMR)

arXiv: https://arxiv.org/abs/2604.06482 · HTML: https://mlsanity.com/paper/2604.06482/

## Key facts

- Cited by 1 papers in the map (data through 14 Oct 2026).
- Builds on 12 of its 70 references that are in the map.
- First posted on arXiv 7 Apr 2026.

## Builds on (most cited first, 12 of 12)

- [Adam: A Method for Stochastic Optimization](https://mlsanity.com/paper/1412.6980/) (2014)
- [PyTorch: An Imperative Style, High-Performance Deep Learning Library](https://mlsanity.com/paper/1912.01703/) (2019)
- [NeRP: Implicit Neural Representation Learning with Prior Embedding for Sparsely Sampled Image Reconstruction](https://mlsanity.com/paper/2108.10991/) (2021)
- [FlashGS: Efficient 3D Gaussian Splatting for Large-scale and High-resolution Rendering](https://mlsanity.com/paper/2408.07967/) (2024)
- [R2-Gaussian: Rectifying Radiative Gaussian Splatting for Tomographic Reconstruction](https://mlsanity.com/paper/2405.20693/) (2024)
- [A survey on deep learning in medical image registration: new technologies, uncertainty, evaluation metrics, and beyond](https://mlsanity.com/paper/2307.15615/) (2023)
- [3DGR-CT: Sparse-View CT Reconstruction with a 3D Gaussian Representation](https://mlsanity.com/paper/2312.15676/) (2023)
- [Extreme MRI: Large-Scale Volumetric Dynamic Imaging from Continuous Non-Gated Acquisitions](https://mlsanity.com/paper/1909.13482/) (2019)
- [Non-rigid 3D motion estimation at high temporal resolution from prospectively undersampled k-space data using low-rank MR-MOTUS](https://mlsanity.com/paper/2007.00488/) (2020)
- [Real-time non-rigid 3D respiratory motion estimation for MR-guided radiotherapy using MR-MOTUS](https://mlsanity.com/paper/2104.07957/) (2021)
- [Time-resolved dynamic CBCT reconstruction using prior-model-free spatiotemporal Gaussian representation (PMF-STGR)](https://mlsanity.com/paper/2503.22139/) (2025)
- [MoRe-3DGSMR: Motion-resolved reconstruction framework for free-breathing pulmonary MRI based on 3D Gaussian representation](https://mlsanity.com/paper/2505.04959/) (2025)

## Built on by (most cited first, 1 of 1)

- [SGAM: Shared Gaussian Geometry with Implicit Amplitude Modeling for Scan-Specific 3D Multi-Contrast MRI Reconstruction](https://mlsanity.com/paper/2609.24468/) (2026)

## Abstract (arXiv)

Time-resolved volumetric MR imaging that reconstructs a 3D MRI within sub-seconds to resolve deformable motion is essential for motion-adaptive radiotherapy. Representing patient anatomy and associated motion fields as 3D Gaussians, we developed a spatiotemporal Gaussian representation-based framework (DREME-GSMR), which enables time-resolved dynamic MRI reconstruction from a pre-treatment 3D MR scan without any prior anatomical/motion model. DREME-GSMR represents a reference MRI volume and a corresponding low-rank motion model (as motion-basis components) using 3D Gaussians, and incorporates a dual-path MLP/CNN motion encoder to estimate temporal motion coefficients of the motion model from raw k-space-derived signals. Furthermore, using the solved motion model, DREME-GSMR can infer motion coefficients directly from new online k-space data, allowing subsequent intra-treatment volumetric MR imaging and motion tracking (real-time imaging). A motion-augmentation strategy is further introduced to improve robustness to unseen motion patterns during real-time imaging. DREME-GSMR was evaluated on the XCAT digital phantom, a physical motion phantom, and MR-LINAC datasets acquired from 6 healthy volunteers and 20 patients (with independent sequential scans for cross-evaluation). DREME-GSMR reconstructs MRIs of a ~400ms temporal resolution, with an inference time of ~10ms/volume. In XCAT experiments, DREME-GSMR achieved mean(s.d.) SSIM, tumor center-of-mass-error(COME), and DSC of 0.92(0.01)/0.91(0.02), 0.50(0.15)/0.65(0.19) mm, and 0.92(0.02)/0.92(0.03) for dynamic reconstruction/real-time imaging. For the physical phantom, the mean target COME was 1.19(0.94)/1.40(1.15) mm for dynamic/real-time imaging, while for volunteers and patients, the mean liver COME for real-time imaging was 1.31(0.82) and 0.96(0.64) mm, respectively.
