# ECG Biometrics with ArcFace-Inception: External Validation on MIMIC and HEEDB

arXiv: https://arxiv.org/abs/2604.04485 · HTML: https://mlsanity.com/paper/2604.04485/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 7 of its 22 references that are in the map.
- First posted on arXiv 6 Apr 2026.

## Builds on (most cited first, 7 of 7)

- [Rethinking the Inception Architecture for Computer Vision](https://mlsanity.com/paper/1512.00567/) (2015)
- [Going Deeper with Convolutions](https://mlsanity.com/paper/1409.4842/) (2014)
- [Fine-tuning CNN Image Retrieval with No Human Annotation](https://mlsanity.com/paper/1711.02512/) (2017)
- [Efficient Diffusion on Region Manifolds: Recovering Small Objects with Compact CNN Representations](https://mlsanity.com/paper/1611.05113/) (2016)
- [ECG Biometric Recognition: Review, System Proposal, and Benchmark Evaluation](https://mlsanity.com/paper/2204.03992/) (2022)
- [ECG Biometric Authentication Using Self-Supervised Learning for IoT Edge Sensors](https://mlsanity.com/paper/2409.05627/) (2024)
- [Verification and Identification in ECG biometric on large-scale](https://mlsanity.com/paper/2602.02776/) (2026)

## Abstract (arXiv)

ECG biometrics has been studied mainly on small cohorts and short inter-session intervals, leaving open how identification behaves under large galleries, external domain shift, and multi-year temporal gaps. We evaluated a 1D Inception-v1 model trained with ArcFace on an internal clinical corpus of 164,440 12-lead ECGs from 53,079 patients and tested it on larger cohorts derived from MIMIC-IV-ECG and HEEDB. The study used a unified closed-set leave-one-out protocol with Rank@K and TAR@FAR metrics, together with scale, temporal-stress, reranking, and confidence analyses. Under general comparability, the system achieved Rank@1 of 0.9506 on ASUGI-DB, 0.8291 on MIMIC-GC, and 0.6884 on HEEDB-GC. In the temporal stress test at constant gallery size, Rank@1 declined from 0.7853 to 0.6433 on MIMIC and from 0.6864 to 0.5560 on HEEDB from 1 to 5 years. Scale analysis on HEEDB showed monotonic degradation as gallery size increased and recovery as more examinations per patient became available. On HEEDB-RR, post-hoc reranking further improved retrieval, with AS-norm reaching Rank@1 = 0.8005 from a 0.7765 baseline. ECG identity information therefore remains measurable under externally validated large-scale closed-set conditions, but its operational quality is strongly affected by domain heterogeneity, longitudinal drift, gallery size, and second-stage score processing.
