# AURORA: Adaptive Unified Representation for Robust Ultrasound Analysis

arXiv: https://arxiv.org/abs/2603.19364 · HTML: https://mlsanity.com/paper/2603.19364/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 8 of its 17 references that are in the map.
- First posted on arXiv 19 Mar 2026.

## Builds on (most cited first, 8 of 8)

- [Segment Anything](https://mlsanity.com/paper/2304.02643/) (2023)
- [SAM 2: Segment Anything in Images and Videos](https://mlsanity.com/paper/2408.00714/) (2024)
- [Qwen3-VL Technical Report](https://mlsanity.com/paper/2511.21631/) (2025)
- [Segment Anything in Medical Images](https://mlsanity.com/paper/2304.12306/) (2023)
- [UltraSam: A Foundation Model for Ultrasound using Large Open-Access Segmentation Datasets](https://mlsanity.com/paper/2411.16222/) (2024)
- [From Pretraining to Privacy: Federated Ultrasound Foundation Model with Self-Supervised Learning](https://mlsanity.com/paper/2411.16380/) (2024)
- [General Methods Make Great Domain-specific Foundation Models: A Case-study on Fetal Ultrasound](https://mlsanity.com/paper/2506.19552/) (2025)
- [Baseline Method of the Foundation Model Challenge for Ultrasound Image Analysis](https://mlsanity.com/paper/2602.01055/) (2026)

## Abstract (arXiv)

Ultrasound images vary widely across scanners, operators, and anatomical targets, which often causes models trained in one setting to generalize poorly to new hospitals and clinical conditions. The Foundation Model Challenge for Ultrasound Image Analysis (FMC-UIA) reflects this difficulty by requiring a single model to handle multiple tasks, including segmentation, detection, classification, and landmark regression across diverse organs and datasets. We propose a unified multi-task framework based on a transformer visual encoder from the Qwen3-VL family. Intermediate token features are projected into spatial feature maps and fused using a lightweight multi-scale feature pyramid, enabling both pixel-level predictions and global reasoning within a shared representation. Each task is handled by a small task-specific prediction head, while training uses task-aware sampling and selective loss balancing to manage heterogeneous supervision and reduce task imbalance. Our method is designed to be simple to optimize and adaptable across a wide range of ultrasound analysis tasks. The performance improved from 67% to 85% on the validation set and achieved an average score of 81.84% on the official test set across all tasks. The code is publicly available at: https://github.com/saitejalekkala33/FMCUIA-ISBI.git
