# CT-Conditioned Diffusion Prior with Physics-Constrained Sampling for PET Super-Resolution

arXiv: https://arxiv.org/abs/2603.13901 · HTML: https://mlsanity.com/paper/2603.13901/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Placed in Medical imaging and segmentation, one of 14 directions in Diffusion models.
- Builds on 8 of its 19 references that are in the map.
- First posted on arXiv 14 Mar 2026.

## Placed in

- Diffusion models / [Medical imaging and segmentation](https://mlsanity.com/diffusion/medical-imaging-and-segmentation/)

## Builds on (most cited first, 8 of 8)

- [Attention Is All You Need](https://mlsanity.com/paper/1706.03762/) (2017)
- [Denoising Diffusion Probabilistic Models](https://mlsanity.com/paper/2006.11239/) (2020)
- [U-Net: Convolutional Networks for Biomedical Image Segmentation](https://mlsanity.com/paper/1505.04597/) (2015)
- [Score-Based Generative Modeling through Stochastic Differential Equations](https://mlsanity.com/paper/2011.13456/) (2020)
- [Diffusion Posterior Sampling for General Noisy Inverse Problems](https://mlsanity.com/paper/2209.14687/) (2022)
- [Score-Based Generative Models for PET Image Reconstruction](https://mlsanity.com/paper/2308.14190/) (2023)
- [Likelihood-Scheduled Score-Based Generative Modeling for Fully 3D PET Image Reconstruction](https://mlsanity.com/paper/2412.04339/) (2024)
- [PET Image Reconstruction Using Deep Diffusion Image Prior](https://mlsanity.com/paper/2507.15078/) (2025)

## Abstract (arXiv)

PET super-resolution is highly under-constrained because paired multi-resolution scans from the same subject are rarely available, and effective resolution is determined by scanner-specific physics (e.g., PSF, detector geometry, and acquisition settings). This limits supervised end-to-end training and makes purely image-domain generative restoration prone to hallucinated structures when anatomical and physical constraints are weak. We formulate PET super-resolution as posterior inference under heterogeneous system configurations and propose a CT-conditioned diffusion framework with physics-constrained sampling. During training, a conditional diffusion prior is learned from high-quality PET/CT pairs using cross-attention for anatomical guidance, without requiring paired LR--HR PET data. During inference, measurement consistency is enforced through a scanner-aware forward model with explicit PSF effects and gradient-based data-consistency refinement. Under both standard and OOD settings, the proposed method consistently improves experimental metrics and lesion-level clinical relevance indicators over strong baselines, while reducing hallucination artifacts and improving structural fidelity.
