# MAP-Diff: Multi-Anchor Guided Diffusion for Progressive 3D Whole-Body Low-Dose PET Denoising

arXiv: https://arxiv.org/abs/2603.02012 · HTML: https://mlsanity.com/paper/2603.02012/

## Key facts

- Cited by 1 papers in the map (data through 14 Oct 2026).
- Placed in Medical imaging and segmentation, one of 14 directions in Diffusion models.
- Builds on 9 of its 22 references that are in the map.
- First posted on arXiv 2 Mar 2026.

## Placed in

- Diffusion models / [Medical imaging and segmentation](https://mlsanity.com/diffusion/medical-imaging-and-segmentation/)

## Builds on (most cited first, 9 of 9)

- [Denoising Diffusion Probabilistic Models](https://mlsanity.com/paper/2006.11239/) (2020)
- [Restormer: Efficient Transformer for High-Resolution Image Restoration](https://mlsanity.com/paper/2111.09881/) (2021)
- [3D U-Net: Learning Dense Volumetric Segmentation from Sparse Annotation](https://mlsanity.com/paper/1606.06650/) (2016)
- [Low-Dose CT with a Residual Encoder-Decoder Convolutional Neural Network (RED-CNN)](https://mlsanity.com/paper/1702.00288/) (2017)
- [PET image denoising based on denoising diffusion probabilistic models](https://mlsanity.com/paper/2209.06167/) (2022)
- [EDCNN: Edge enhancement-based Densely Connected Network with Compound Loss for Low-Dose CT Denoising](https://mlsanity.com/paper/2011.00139/) (2020)
- [Spach Transformer: Spatial and Channel-wise Transformer Based on Local and Global Self-attentions for PET Image Denoising](https://mlsanity.com/paper/2209.03300/) (2022)
- [LIT-Former: Linking In-plane and Through-plane Transformers for Simultaneous CT Image Denoising and Deblurring](https://mlsanity.com/paper/2302.10630/) (2023)
- [DRMC: A Generalist Model with Dynamic Routing for Multi-Center PET Image Synthesis](https://mlsanity.com/paper/2307.05249/) (2023)

## Built on by (most cited first, 1 of 1)

- [MARR: Decoupling Policy, Execution, and Calibration for All-in-One Medical Image Restoration](https://mlsanity.com/paper/2609.06645/) (2026)

## Abstract (arXiv)

Low-dose Positron Emission Tomography (PET) reduces radiation exposure but suffers from severe noise and quantitative degradation. Diffusion-based denoising models achieve strong final reconstructions, yet their reverse trajectories are typically unconstrained and not aligned with the progressive nature of PET dose formation. We propose MAP-Diff, a multi-anchor guided diffusion framework for progressive 3D whole-body PET denoising. MAP-Diff introduces clinically observed intermediate-dose scans as trajectory anchors and enforces timestep-dependent supervision to regularize the reverse process toward dose-aligned intermediate states. Anchor timesteps are calibrated via degradation matching between simulated diffusion corruption and real multi-dose PET pairs, and a timestep-weighted anchor loss stabilizes stage-wise learning. At inference, the model requires only ultra-low-dose input while enabling progressive, dose-consistent intermediate restoration. Experiments on internal (Siemens Biograph Vision Quadra) and cross-scanner (United Imaging uEXPLORER) datasets show consistent improvements over strong CNN-, Transformer-, GAN-, and diffusion-based baselines. On the internal dataset, MAP-Diff improves PSNR from 42.48 dB to 43.71 dB (+1.23 dB), increases SSIM to 0.986, and reduces NMAE from 0.115 to 0.103 (-0.012) compared to 3D DDPM. Performance gains generalize across scanners, achieving 34.42 dB PSNR and 0.141 NMAE on the external cohort, outperforming all competing methods.
