# SCAR: Satellite Imagery-Based Calibration for Aerial Recordings

arXiv: https://arxiv.org/abs/2602.16349 · HTML: https://mlsanity.com/paper/2602.16349/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 9 of its 31 references that are in the map.
- First posted on arXiv 18 Feb 2026.

## Builds on (most cited first, 9 of 9)

- [SuperPoint: Self-Supervised Interest Point Detection and Description](https://mlsanity.com/paper/1712.07629/) (2017)
- [LightGlue: Local Feature Matching at Light Speed](https://mlsanity.com/paper/2306.13643/) (2023)
- [VINS-Mono: A Robust and Versatile Monocular Visual-Inertial State Estimator](https://mlsanity.com/paper/1708.03852/) (2017)
- [RoMa: Robust Dense Feature Matching](https://mlsanity.com/paper/2305.15404/) (2023)
- [MAGSAC++, a fast, reliable and accurate robust estimator](https://mlsanity.com/paper/1912.05909/) (2019)
- [Visual-Inertial Navigation: A Concise Review](https://mlsanity.com/paper/1906.02650/) (2019)
- [On 'A Kalman Filter-Based Algorithm for IMU-Camera Calibration: Observability Analysis and Performance Evaluation'](https://mlsanity.com/paper/1311.4769/) (2013)
- [Distributed Global Structure-from-Motion with a Deep Front-End](https://mlsanity.com/paper/2311.18801/) (2023)
- [Visual-inertial self-calibration on informative motion segments](https://mlsanity.com/paper/1708.02382/) (2017)

## Abstract (arXiv)

We introduce SCAR, a method for long-term auto-calibration refinement of aerial visual-inertial systems that exploits georeferenced satellite imagery as a persistent global reference. SCAR estimates both intrinsic and extrinsic parameters by aligning aerial images with 2D--3D correspondences derived from publicly available orthophotos and elevation models. In contrast to existing approaches that rely on dedicated calibration maneuvers or manually surveyed ground control points, our method leverages external geospatial data to detect and correct calibration degradation under field deployment conditions. We evaluate our approach on six large-scale aerial campaigns conducted over two years under diverse seasonal and environmental conditions. Across all sequences, SCAR consistently outperforms established baselines (Kalibr, COLMAP, VINS-Mono), reducing median reprojection error by a large margin, and translating these calibration gains into substantially lower visual localization rotation errors and higher pose accuracy. These results demonstrate that SCAR provides accurate, robust, and reproducible calibration over long-term aerial operations without the need for manual intervention.
