# Automated Assessment of Kidney Ureteroscopy Exploration for Training

arXiv: https://arxiv.org/abs/2602.15988 · HTML: https://mlsanity.com/paper/2602.15988/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 8 of its 22 references that are in the map.
- First posted on arXiv 17 Feb 2026.

## Builds on (most cited first, 8 of 8)

- [NetVLAD: CNN architecture for weakly supervised place recognition](https://mlsanity.com/paper/1511.07247/) (2015)
- [From Coarse to Fine: Robust Hierarchical Localization at Large Scale](https://mlsanity.com/paper/1812.03506/) (2018)
- [ALIKED: A Lighter Keypoint and Descriptor Extraction Network via Deformable Transformation](https://mlsanity.com/paper/2304.03608/) (2023)
- [Tracking and Mapping in Medical Computer Vision: A Review](https://mlsanity.com/paper/2310.11475/) (2023)
- [BronchoTrack: Airway Lumen Tracking for Branch-Level Bronchoscopic Localization](https://mlsanity.com/paper/2402.12763/) (2024)
- [3D Reconstruction of Whole Stomach from Endoscope Video Using Structure-from-Motion](https://mlsanity.com/paper/1905.12988/) (2019)
- [From Monocular Vision to Autonomous Action: Guiding Tumor Resection via 3D Reconstruction](https://mlsanity.com/paper/2503.16263/) (2025)
- [NAVIUS: Navigated Augmented Reality Visualization for Ureteroscopic Surgery](https://mlsanity.com/paper/2503.17511/) (2025)

## Abstract (arXiv)

Purpose: Kidney ureteroscopic navigation is challenging with a steep learning curve. However, current clinical training has major deficiencies, as it requires one-on-one feedback from experts and occurs in the operating room (OR). Therefore, there is a need for a phantom training system with automated feedback to greatly revisionexpand training opportunities. Methods: We propose a novel, purely ureteroscope video-based scope localization framework that automatically identifies calyces missed by the trainee in a phantom kidney exploration. We use a slow, thorough, prior exploration video of the kidney to generate a reference reconstruction. Then, this reference reconstruction can be used to localize any exploration video of the same phantom. Results: In 15 exploration videos, a total of 69 out of 74 calyces were correctly classified. We achieve < 4mm camera pose localization error. Given the reference reconstruction, the system takes 10 minutes to generate the results for a typical exploration (1-2 minute long). Conclusion: We demonstrate a novel camera localization framework that can provide accurate and automatic feedback for kidney phantom explorations. We show its ability as a valid tool that enables out-of-OR training without requiring supervision from an expert.
