# AI-Based Detection of Temporal Changes in MR-Linac Images Acquired During Routine Prostate Radiotherapy

arXiv: https://arxiv.org/abs/2602.04983 · HTML: https://mlsanity.com/paper/2602.04983/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 5 of its 34 references that are in the map.
- First posted on arXiv 4 Feb 2026.

## Builds on (most cited first, 5 of 5)

- [Deep Residual Learning for Image Recognition](https://mlsanity.com/paper/1512.03385/) (2015)
- [Adam: A Method for Stochastic Optimization](https://mlsanity.com/paper/1412.6980/) (2014)
- [Grad-CAM: Visual Explanations from Deep Networks via Gradient-based Localization](https://mlsanity.com/paper/1610.02391/) (2016)
- [A Survey on Deep Learning in Medical Image Analysis](https://mlsanity.com/paper/1702.05747/) (2017)
- [Learning to Compare Longitudinal Images](https://mlsanity.com/paper/2304.02531/) (2023)

## Abstract (arXiv)

Purpose: To investigate whether an AI-based method can detect subtle inter-fraction changes in MR-Linac images acquired during radiotherapy and explore the broader potential of MRLinac imaging. Methods: This retrospective study included longitudinal 0.35T MR-Linac images from 761 patients. To identify temporal changes, we employed a deep learning model using temporal ordering via pairwise comparison, previously shown effective for longitudinal imaging studies. The model was trained using first-to-last fraction pairs (F1-FL) and all pairs (All-pairs). Performance was assessed using quantitative metrics (accuracy and AUC) and compared against a radiologist's performance. Qualitative evaluation was performed using saliency maps, which identify anatomical regions associated with temporal imaging changes. Results: The F1-FL model demonstrated high performance (AUC=0.99, accuracy=0.95) and outperformed the radiologist in temporal ordering task. The All-pairs model also showed high performance (AUC=0.97, accuracy=0.91). Regions contributing to predictions included the prostate, bladder, and pubic symphysis. The performance was correlated to fractional intervals and was reduced for non-radiation-exposed timepoints (Sim and F1), suggesting that observed changes may reflect both temporal variation and radiation exposure. Conclusion: MR-Linac imaging appears capable of capturing subtle changes during prostate radiotherapy that can be detected by AI models, even over approximately two-day intervals. The model's high performance, together with quantitative and qualitative analyses, supports a potential role for MR-Linac in clinical applications beyond image guidance.