# Low performing pixel correction in computed tomography with unrolled network and synthetic data training

arXiv: https://arxiv.org/abs/2601.20995 · HTML: https://mlsanity.com/paper/2601.20995/

## Key facts

- Cited by 1 papers in the map (data through 14 Oct 2026).
- Builds on 8 of its 15 references that are in the map.
- First posted on arXiv 28 Jan 2026.

## Builds on (most cited first, 8 of 8)

- [ImageNet Large Scale Visual Recognition Challenge](https://mlsanity.com/paper/1409.0575/) (2014)
- [3D U-Net: Learning Dense Volumetric Segmentation from Sparse Annotation](https://mlsanity.com/paper/1606.06650/) (2016)
- [Simple Baselines for Image Restoration](https://mlsanity.com/paper/2204.04676/) (2022)
- [Multivariate mixture model for myocardium segmentation combining multi-source images](https://mlsanity.com/paper/1612.08820/) (2016)
- [TorchRadon: Fast Differentiable Routines for Computed Tomography](https://mlsanity.com/paper/2009.14788/) (2020)
- [Deep Rib Fracture Instance Segmentation and Classification from CT on the RibFrac Challenge](https://mlsanity.com/paper/2402.09372/) (2024)
- [Ring Artifacts Removal Based on Implicit Neural Representation of Sinogram Data](https://mlsanity.com/paper/2409.15731/) (2024)
- [Unsupervised Multi-Parameter Inverse Solving for Reducing Ring Artifacts in 3D X-Ray CBCT](https://mlsanity.com/paper/2412.05853/) (2024)

## Built on by (most cited first, 1 of 1)

- [SynthRAR: Ring Artifacts Reduction in CT with Unrolled Network and Synthetic Data Training](https://mlsanity.com/paper/2602.11880/) (2026)

## Abstract (arXiv)

Low performance pixels (LPP) in Computed Tomography (CT) detectors would lead to ring and streak artifacts in the reconstructed images, making them clinically unusable. In recent years, several solutions have been proposed to correct LPP artifacts, either in the image domain or in the sinogram domain using supervised deep learning methods. However, these methods require dedicated datasets for training, which are expensive to collect. Moreover, existing approaches focus solely either on image-space or sinogram-space correction, ignoring the intrinsic correlations from the forward operation of the CT geometry. In this work, we propose an unrolled dual-domain method based on synthetic data to correct LPP artifacts. Specifically, the intrinsic correlations of LPP between the sinogram and image domains are leveraged through synthetic data generated from natural images, enabling the trained model to correct artifacts without requiring any real-world clinical data. In experiments simulating 1-2% detectors defect near the isocenter, the proposed method outperformed the state-of-the-art approaches by a large margin. The results indicate that our solution can correct LPP artifacts without the cost of data collection for model training, and it is adaptable to different scanner settings for software-based applications.
