# PUNCH: Physics-informed Uncertainty-aware Network for Coronary Hemodynamics

arXiv: https://arxiv.org/abs/2601.17192 · HTML: https://mlsanity.com/paper/2601.17192/

## Key facts

- Cited by 1 papers in the map (data through 14 Oct 2026).
- Builds on 7 of its 52 references that are in the map.
- First posted on arXiv 23 Jan 2026.

## Builds on (most cited first, 7 of 7)

- [Dropout as a Bayesian Approximation: Representing Model Uncertainty in Deep Learning](https://mlsanity.com/paper/1506.02142/) (2015)
- [CoTracker: It is Better to Track Together](https://mlsanity.com/paper/2307.07635/) (2023)
- [Adversarial Uncertainty Quantification in Physics-Informed Neural Networks](https://mlsanity.com/paper/1811.04026/) (2018)
- [Dynamic Snake Convolution based on Topological Geometric Constraints for Tubular Structure Segmentation](https://mlsanity.com/paper/2307.08388/) (2023)
- [Local All-Pair Correspondence for Point Tracking](https://mlsanity.com/paper/2407.15420/) (2024)
- [SAM2-UNet: Segment Anything 2 Makes Strong Encoder for Natural and Medical Image Segmentation](https://mlsanity.com/paper/2408.08870/) (2024)
- [Bayesian Physics-Informed Neural Networks for real-world nonlinear dynamical systems](https://mlsanity.com/paper/2205.08304/) (2022)

## Built on by (most cited first, 1 of 1)

- [Wall Shear Stress Reconstruction from Concentration: Differentiable Physics and Physics-Informed Neural Networks](https://mlsanity.com/paper/2606.06313/) (2026)

## Abstract (arXiv)

More than 10 million coronary angiograms are performed globally each year, providing a gold standard for detecting obstructive coronary artery disease. Yet, no obstructive lesions are identified in 70% of patients evaluated for ischemic heart disease. Up to half of these patients have undiagnosed, life-limiting coronary microvascular dysfunction (CMD), which remains under-detected due to the limited availability of invasive tools required to measure coronary flow reserve (CFR). Here, we introduce PUNCH, a non-invasive, uncertainty-aware framework for estimating CFR directly from standard coronary angiography. PUNCH integrates physics-informed neural networks with variational inference to infer coronary blood flow from first-principles models of contrast transport, without requiring ground-truth flow measurements or population-level training. The pipeline runs in approximately three minutes per patient on a single GPU. Validated on synthetic angiograms with controlled noise and imaging artifacts, as well as on clinical bolus thermodilution data from 20 patients, PUNCH demonstrates accurate and uncertainty-calibrated CFR estimation. This approach establishes a new paradigm for CMD diagnosis and illustrates how physics-informed inference can substantially expand the diagnostic utility of available clinical imaging.
