# Multi-task Cross-modal Learning for Chest X-ray Image Retrieval

arXiv: https://arxiv.org/abs/2601.05399 · HTML: https://mlsanity.com/paper/2601.05399/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 7 of its 17 references that are in the map.
- First posted on arXiv 8 Jan 2026.

## Builds on (most cited first, 7 of 7)

- [Learning Transferable Visual Models From Natural Language Supervision](https://mlsanity.com/paper/2103.00020/) (2021)
- [BLIP-2: Bootstrapping Language-Image Pre-training with Frozen Image Encoders and Large Language Models](https://mlsanity.com/paper/2301.12597/) (2023)
- [BLIP: Bootstrapping Language-Image Pre-training for Unified Vision-Language Understanding and Generation](https://mlsanity.com/paper/2201.12086/) (2022)
- [Supervised Contrastive Learning](https://mlsanity.com/paper/2004.11362/) (2020)
- [Billion-scale similarity search with GPUs](https://mlsanity.com/paper/1702.08734/) (2017)
- [Towards Building Multilingual Language Model for Medicine](https://mlsanity.com/paper/2402.13963/) (2024)
- [Significantly improving zero-shot X-ray pathology classification via fine-tuning pre-trained image-text encoders](https://mlsanity.com/paper/2212.07050/) (2022)

## Abstract (arXiv)

CLIP and BiomedCLIP are examples of vision-language foundation models and offer strong cross-modal embeddings; however, they are not optimized for fine-grained medical retrieval tasks, such as retrieving clinically relevant radiology reports using chest X-ray (CXR) image queries. To address this shortcoming, we propose a multi-task learning framework to fine-tune BiomedCLIP and evaluate improvements to CXR image-text retrieval. Using BiomedCLIP as the backbone, we incorporate a lightweight MLP projector head trained with a multi-task composite loss function that includes: (1) a binary cross-entropy loss to distinguish normal from abnormal CXR studies, (2) a supervised contrastive loss to reinforce intra-class consistency, and (3) a CLIP loss to maintain cross-modal alignment. Experimental results demonstrate that the fine-tuned model achieves more balanced and clinically meaningful performance across both image-to-text and text-to-image retrieval tasks compared to the pretrained BiomedCLIP and general-purpose CLIP models. Furthermore, t-SNE visualizations reveal clearer semantic clustering of normal and abnormal cases, demonstrating the model's enhanced diagnostic sensitivity. These findings highlight the value of domain-adaptive, multi-task learning for advancing cross-modal retrieval in biomedical applications.