# Learning-Based Estimation of Spatially Resolved Scatter Radiation Fields in Interventional Radiology

arXiv: https://arxiv.org/abs/2512.17654 · HTML: https://mlsanity.com/paper/2512.17654/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 10 of its 45 references that are in the map.
- First posted on arXiv 19 Dec 2025.

## Builds on (most cited first, 10 of 10)

- [Attention Is All You Need](https://mlsanity.com/paper/1706.03762/) (2017)
- [U-Net: Convolutional Networks for Biomedical Image Segmentation](https://mlsanity.com/paper/1505.04597/) (2015)
- [SGDR: Stochastic Gradient Descent with Warm Restarts](https://mlsanity.com/paper/1608.03983/) (2016)
- [Instant Neural Graphics Primitives with a Multiresolution Hash Encoding](https://mlsanity.com/paper/2201.05989/) (2022)
- [Optuna: A Next-generation Hyperparameter Optimization Framework](https://mlsanity.com/paper/1907.10902/) (2019)
- [FiLM: Visual Reasoning with a General Conditioning Layer](https://mlsanity.com/paper/1709.07871/) (2017)
- [3D U-Net: Learning Dense Volumetric Segmentation from Sparse Annotation](https://mlsanity.com/paper/1606.06650/) (2016)
- [Cyclical Learning Rates for Training Neural Networks](https://mlsanity.com/paper/1506.01186/) (2015)
- [Deep Dose Plugin Towards Real-time Monte Carlo Dose Calculation Through a Deep Learning based Denoising Algorithm](https://mlsanity.com/paper/2011.14959/) (2020)
- [RadField3D: A Data Generator and Data Format for Deep Learning in Radiation-Protection Dosimetry for Medical Applications](https://mlsanity.com/paper/2412.13852/) (2024)

## Abstract (arXiv)

We present three variants of a lightweight, fully connected artificial neural network, suited for interactive estimation of three-dimensional, spatially resolved volumes of scattered radiation fields and a corresponding training pipeline for radiation protection dosimetry in medical radiation fields, such as those found in interventional radiology and cardiology. Accompanying, we present three different synthetically generated datasets with increasing complexity for training, generated using RadField3D, a Monte Carlo simulation application based on Geant4. As the primary scatter object, we employed the torso of a male Alderson RANDO phantom. On those datasets, we evaluate convolutional and fully connected architectures of neural networks to demonstrate which design decisions work well for reconstructing the fluence and spectra distributions over the spatial domain of such radiation fields. All our datasets, as well as our training pipeline, are published as open source in separate repositories. To evaluate the presented neural networks, we define and assess several metrics. Across these measures, the model variants demonstrate good spatial agreement between predicted and ground-truth radiation fields, particularly within specific regions of interest within the radiation field. Of particular relevance for potential application in out-of-field dosimetry is the SMAPE of the scatter radiation field, which represents the most challenging metric and was consistently above 84 %.
