# A Hierarchical Computer Vision Pipeline for Physiological Data Extraction from Bedside Monitors

arXiv: https://arxiv.org/abs/2511.23355 · HTML: https://mlsanity.com/paper/2511.23355/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 5 of its 20 references that are in the map.
- First posted on arXiv 28 Nov 2025.

## Builds on (most cited first, 5 of 5)

- [A Survey on Deep Learning in Medical Image Analysis](https://mlsanity.com/paper/1702.05747/) (2017)
- [YOLOv11: An Overview of the Key Architectural Enhancements](https://mlsanity.com/paper/2410.17725/) (2024)
- [PaddleOCR 3.0 Technical Report](https://mlsanity.com/paper/2507.05595/) (2025)
- [YOLO Evolution: A Comprehensive Benchmark and Architectural Review of YOLOv12, YOLO11, and Their Previous Versions](https://mlsanity.com/paper/2411.00201/) (2024)
- [Leveraging Computer Vision in the Intensive Care Unit (ICU) for Examining Visitation and Mobility](https://mlsanity.com/paper/2403.06322/) (2024)

## Abstract (arXiv)

In many low-resource healthcare settings, bedside monitors remain standalone legacy devices without network connectivity, creating a persistent interoperability gap that prevents seamless integration of physiological data into electronic health record (EHR) systems. To address this challenge without requiring costly hardware replacement, we present a computer vision-based pipeline for the automated capture and digitisation of vital sign data directly from bedside monitor screens. Our method employs a hierarchical detection framework combining YOLOv11 for accurate monitor and region of interest (ROI) localisation with PaddleOCR for robust text extraction. To enhance reliability across variable camera angles and lighting conditions, a geometric rectification module standardizes the screen perspective before character recognition. We evaluated the system on a dataset of 6,498 images collected from open-source corpora and real-world intensive care units in Vietnam. The model achieved a mean Average Precision (mAP@50-95) of 99.5% for monitor detection and 91.5% for vital sign ROI localisation. The end-to-end extraction accuracy exceeded 98.9% for core physiological parameters, including heart rate, oxygen saturation SpO2, and arterial blood pressure. These results demonstrate that a lightweight, camera-based approach can reliably transform unstructured information from screen captures into structured digital data, providing a practical and scalable pathway to improve information accessibility and clinical documentation in low-resource settings.
