# Gated Uncertainty-Aware Runtime Dual Invariants for Neural Signal-Controlled Robotics

arXiv: https://arxiv.org/abs/2511.20570 · HTML: https://mlsanity.com/paper/2511.20570/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 10 of its 32 references that are in the map.
- First posted on arXiv 25 Nov 2025.

## Builds on (most cited first, 10 of 10)

- [PyTorch: An Imperative Style, High-Performance Deep Learning Library](https://mlsanity.com/paper/1912.01703/) (2019)
- [On Calibration of Modern Neural Networks](https://mlsanity.com/paper/1706.04599/) (2017)
- [EEGNet: A Compact Convolutional Network for EEG-based Brain-Computer Interfaces](https://mlsanity.com/paper/1611.08024/) (2016)
- [Safe Reinforcement Learning via Shielding](https://mlsanity.com/paper/1708.08611/) (2017)
- [Revisiting the Calibration of Modern Neural Networks](https://mlsanity.com/paper/2106.07998/) (2021)
- [MOABB: Trustworthy algorithm benchmarking for BCIs](https://mlsanity.com/paper/1805.06427/) (2018)
- [Shared Autonomy via Hindsight Optimization for Teleoperation and Teaming](https://mlsanity.com/paper/1706.00155/) (2017)
- [Transfer Learning in Brain-Computer Interfaces](https://mlsanity.com/paper/1512.00296/) (2015)
- [NOIR: Neural Signal Operated Intelligent Robots for Everyday Activities](https://mlsanity.com/paper/2311.01454/) (2023)
- [Guiding Soft Robots with Motor-Imagery Brain Signals and Impedance Control](https://mlsanity.com/paper/2401.13441/) (2024)

## Abstract (arXiv)

Safety-critical assistive systems that directly decode user intent from neural signals require rigorous guarantees of reliability and trust. We present GUARDIAN (Gated Uncertainty-Aware Runtime Dual Invariants), a framework for real-time neuro-symbolic verification for neural signal-controlled robotics. GUARDIAN enforces both logical safety and physiological trust by coupling confidence-calibrated brain signal decoding with symbolic goal grounding and dual-layer runtime monitoring. On the BNCI2014 motor imagery electroencephalogram (EEG) dataset with 9 subjects and 5,184 trials, the system performs at a high safety rate of 94-97% even with lightweight decoder architectures with low test accuracies (27-46%) and high ECE confidence miscalibration (0.22-0.41). We demonstrate 1.7x correct interventions in simulated noise testing versus at baseline. The monitor operates at 100Hz and sub-millisecond decision latency, making it practically viable for closed-loop neural signal-based systems. Across 21 ablation results, GUARDIAN exhibits a graduated response to signal degradation, and produces auditable traces from intent, plan to action, helping to link neural evidence to verifiable robot action.
