# Regional Attention-Enhanced Swin Transformer for Clinically Relevant Medical Image Captioning

arXiv: https://arxiv.org/abs/2511.09893 · HTML: https://mlsanity.com/paper/2511.09893/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 10 of its 20 references that are in the map.
- First posted on arXiv 13 Nov 2025.

## Builds on (most cited first, 10 of 10)

- [Attention Is All You Need](https://mlsanity.com/paper/1706.03762/) (2017)
- [Swin Transformer: Hierarchical Vision Transformer using Shifted Windows](https://mlsanity.com/paper/2103.14030/) (2021)
- [BLIP-2: Bootstrapping Language-Image Pre-training with Frozen Image Encoders and Large Language Models](https://mlsanity.com/paper/2301.12597/) (2023)
- [BART: Denoising Sequence-to-Sequence Pre-training for Natural Language Generation, Translation, and Comprehension](https://mlsanity.com/paper/1910.13461/) (2019)
- [BLIP: Bootstrapping Language-Image Pre-training for Unified Vision-Language Understanding and Generation](https://mlsanity.com/paper/2201.12086/) (2022)
- [Domain-Specific Language Model Pretraining for Biomedical Natural Language Processing](https://mlsanity.com/paper/2007.15779/) (2020)
- [Learning to Exploit Temporal Structure for Biomedical Vision-Language Processing](https://mlsanity.com/paper/2301.04558/) (2023)
- [MedBLIP: Bootstrapping Language-Image Pre-training from 3D Medical Images and Texts](https://mlsanity.com/paper/2305.10799/) (2023)
- [Advancing Autonomous Driving: DepthSense with Radar and Spatial Attention](https://mlsanity.com/paper/2109.05265/) (2021)
- [DS@BioMed at ImageCLEFmedical Caption 2024: Enhanced Attention Mechanisms in Medical Caption Generation through Concept Detection Integration](https://mlsanity.com/paper/2406.00391/) (2024)

## Abstract (arXiv)

Automated medical image captioning translates complex radiological images into diagnostic narratives that can support reporting workflows. We present a Swin-BART encoder-decoder system with a lightweight regional attention module that amplifies diagnostically salient regions before cross-attention. Trained and evaluated on ROCO, our model achieves state-of-the-art semantic fidelity while remaining compact and interpretable. We report results as mean±std over three seeds and include 95% confidence intervals. Compared with baselines, our approach improves ROUGE (proposed 0.603, ResNet-CNN 0.356, BLIP2-OPT 0.255) and BERTScore (proposed 0.807, BLIP2-OPT 0.645, ResNet-CNN 0.623), with competitive BLEU, CIDEr, and METEOR. We further provide ablations (regional attention on/off and token-count sweep), per-modality analysis (CT/MRI/X-ray), paired significance tests, and qualitative heatmaps that visualize the regions driving each description. Decoding uses beam search (beam size =4), length penalty =1.1, norepeatngramsize =3, and max length =128. The proposed design yields accurate, clinically phrased captions and transparent regional attributions, supporting safe research use with a human in the loop.
