# Scanner-Agnostic MRI Harmonization via SSIM-Guided Disentanglement

arXiv: https://arxiv.org/abs/2510.22073 · HTML: https://mlsanity.com/paper/2510.22073/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 7 of its 24 references that are in the map.
- First posted on arXiv 24 Oct 2025.

## Builds on (most cited first, 7 of 7)

- [Deep Residual Learning for Image Recognition](https://mlsanity.com/paper/1512.03385/) (2015)
- [StarGAN v2: Diverse Image Synthesis for Multiple Domains](https://mlsanity.com/paper/1912.01865/) (2019)
- [Scanner Invariant Representations for Diffusion MRI Harmonization](https://mlsanity.com/paper/1904.05375/) (2019)
- [Learning Multi-Site Harmonization of Magnetic Resonance Images Without Traveling Human Phantoms](https://mlsanity.com/paper/2110.00041/) (2021)
- [Attribute Guided Unpaired Image-to-Image Translation with Semi-supervised Learning](https://mlsanity.com/paper/1904.12428/) (2019)
- [IGUANe: a 3D generalizable CycleGAN for multicenter harmonization of brain MR images](https://mlsanity.com/paper/2402.03227/) (2024)
- [DISARM++: Beyond scanner-free harmonization](https://mlsanity.com/paper/2505.03715/) (2025)

## Abstract (arXiv)

The variability introduced by differences in MRI scanner models, acquisition protocols, and imaging sites hinders consistent analysis and generalizability across multicenter studies. We present a novel image-based harmonization framework for 3D T1-weighted brain MRI, which disentangles anatomical content from scanner- and site-specific variations. The model incorporates a differentiable loss based on the Structural Similarity Index (SSIM) to preserve biologically meaningful features while reducing inter-site variability. This loss enables separate evaluation of image luminance, contrast, and structural components. Training and validation were performed on multiple publicly available datasets spanning diverse scanners and sites, with testing on both healthy and clinical populations. Harmonization using multiple style targets, including style-agnostic references, produced consistent and high-quality outputs. Visual comparisons, voxel intensity distributions, and SSIM-based metrics demonstrated that harmonized images achieved strong alignment across acquisition settings while maintaining anatomical fidelity. Following harmonization, structural SSIM reached 0.97, luminance SSIM ranged from 0.98 to 0.99, and Wasserstein distances between mean voxel intensity distributions decreased substantially. Downstream tasks showed substantial improvements: mean absolute error for brain age prediction decreased from 5.36 to 3.30 years, and Alzheimer's disease classification AUC increased from 0.78 to 0.85. Overall, our framework enhances cross-site image consistency, preserves anatomical fidelity, and improves downstream model performance, providing a robust and generalizable solution for large-scale multicenter neuroimaging studies.
