# Radiology Report Conditional 3D CT Generation with Multi Encoder Latent diffusion Model

arXiv: https://arxiv.org/abs/2509.14780 · HTML: https://mlsanity.com/paper/2509.14780/

## Key facts

- Cited by 3 papers in the map (data through 14 Oct 2026).
- Placed in Medical imaging and segmentation, one of 14 directions in Diffusion models.
- Builds on 20 of its 33 references that are in the map.
- First posted on arXiv 18 Sep 2025.

## Placed in

- Diffusion models / [Medical imaging and segmentation](https://mlsanity.com/diffusion/medical-imaging-and-segmentation/)

## Builds on (most cited first, 20 of 20)

- [High-Resolution Image Synthesis with Latent Diffusion Models](https://mlsanity.com/paper/2112.10752/) (2021)
- [Classifier-Free Diffusion Guidance](https://mlsanity.com/paper/2207.12598/) (2022)
- [Scaling Rectified Flow Transformers for High-Resolution Image Synthesis](https://mlsanity.com/paper/2403.03206/) (2024)
- [ClinicalBERT: Modeling Clinical Notes and Predicting Hospital Readmission](https://mlsanity.com/paper/1904.05342/) (2019)
- [MONAI: An open-source framework for deep learning in healthcare](https://mlsanity.com/paper/2211.02701/) (2022)
- [Making the Most of Text Semantics to Improve Biomedical Vision--Language Processing](https://mlsanity.com/paper/2204.09817/) (2022)
- [Diffusion Models for Medical Image Analysis: A Comprehensive Survey](https://mlsanity.com/paper/2211.07804/) (2022)
- [Generalist Foundation Models from a Multimodal Dataset for 3D Computed Tomography](https://mlsanity.com/paper/2403.17834/) (2024)
- [RoentGen: Vision-Language Foundation Model for Chest X-ray Generation](https://mlsanity.com/paper/2211.12737/) (2022)
- [MAISI: Medical AI for Synthetic Imaging](https://mlsanity.com/paper/2409.11169/) (2024)
- [Transparency of Deep Neural Networks for Medical Image Analysis: A Review of Interpretability Methods](https://mlsanity.com/paper/2111.02398/) (2021)
- [Diffusion Probabilistic Models beat GANs on Medical Images](https://mlsanity.com/paper/2212.07501/) (2022)
- [Generative AI for Medical Imaging: extending the MONAI Framework](https://mlsanity.com/paper/2307.15208/) (2023)
- [GenerateCT: Text-Conditional Generation of 3D Chest CT Volumes](https://mlsanity.com/paper/2305.16037/) (2023)
- [MedSyn: Text-guided Anatomy-aware Synthesis of High-Fidelity 3D CT Images](https://mlsanity.com/paper/2310.03559/) (2023)
- [Generative AI for Synthetic Data Across Multiple Medical Modalities: A Systematic Review of Recent Developments and Challenges](https://mlsanity.com/paper/2407.00116/) (2024)
- [Chest-Diffusion: A Light-Weight Text-to-Image Model for Report-to-CXR Generation](https://mlsanity.com/paper/2407.00752/) (2024)
- [Text2CT: Towards 3D CT Volume Generation from Free-text Descriptions Using Diffusion Model](https://mlsanity.com/paper/2505.04522/) (2025)
- [A Generalist Model for Diverse Text-Guided Medical Image Synthesis](https://mlsanity.com/paper/2405.09806/) (2024)
- [From Alignment to Synthesis: Contrastive Volumetric Grounding for Text-to-CT Generation](https://mlsanity.com/paper/2506.00633/) (2025)

## Built on by (most cited first, 3 of 3)

- [Retrieval-Augmented Anatomical Guidance for Text-to-CT Generation](https://mlsanity.com/paper/2603.08305/) (2026)
- [Knowledge-Guided 3D CT Generation: A Conditioning-Centric Taxonomy](https://mlsanity.com/paper/2608.09992/) (2026)
- [MedSyn2: Flexible Control of 3D CT Generation via Text and Semantically-Defined Segmentation Prompts](https://mlsanity.com/paper/2606.00967/) (2026)

## Abstract (arXiv)

Text to image latent diffusion models have recently advanced medical image synthesis, but applications to 3D CT generation remain limited. Existing approaches rely on simplified prompts, neglecting the rich semantic detail in full radiology reports, which reduces text image alignment and clinical fidelity. We propose Report2CT, a radiology report conditional latent diffusion framework for synthesizing 3D chest CT volumes directly from free text radiology reports, incorporating both findings and impression sections using multiple text encoder. Report2CT integrates three pretrained medical text encoders (BiomedVLP CXR BERT, MedEmbed, and ClinicalBERT) to capture nuanced clinical context. Radiology reports and voxel spacing information condition a 3D latent diffusion model trained on 20000 CT volumes from the CT RATE dataset. Model performance was evaluated using Frechet Inception Distance (FID) for real synthetic distributional similarity and CLIP based metrics for semantic alignment, with additional qualitative and quantitative comparisons against GenerateCT model. Report2CT generated anatomically consistent CT volumes with excellent visual quality and text image alignment. Multi encoder conditioning improved CLIP scores, indicating stronger preservation of fine grained clinical details in the free text radiology reports. Classifier free guidance further enhanced alignment with only a minor trade off in FID. We ranked first in the VLM3D Challenge at MICCAI 2025 on Text Conditional CT Generation and achieved state of the art performance across all evaluation metrics. By leveraging complete radiology reports and multi encoder text conditioning, Report2CT advances 3D CT synthesis, producing clinically faithful and high quality synthetic data.
