# Beam Geometry and Input Dimensionality: Impact on Sparse-Sampling Artifact Correction for Clinical CT with U-Nets

arXiv: https://arxiv.org/abs/2508.17961 · HTML: https://mlsanity.com/paper/2508.17961/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 8 of its 23 references that are in the map.
- First posted on arXiv 25 Aug 2025.

## Builds on (most cited first, 8 of 8)

- [U-Net: Convolutional Networks for Biomedical Image Segmentation](https://mlsanity.com/paper/1505.04597/) (2015)
- [3D U-Net: Learning Dense Volumetric Segmentation from Sparse Annotation](https://mlsanity.com/paper/1606.06650/) (2016)
- [Framing U-Net via Deep Convolutional Framelets: Application to Sparse-view CT](https://mlsanity.com/paper/1708.08333/) (2017)
- [Multi-view 3D Reconstruction with Transformer](https://mlsanity.com/paper/2103.12957/) (2021)
- [2.5D Deep Learning for CT Image Reconstruction using a Multi-GPU implementation](https://mlsanity.com/paper/1812.08367/) (2018)
- [WNet: A data-driven dual-domain denoising model for sparse-view computed tomography with a trainable reconstruction layer](https://mlsanity.com/paper/2207.00400/) (2022)
- [Improving Automated Hemorrhage Detection in Sparse-view Computed Tomography via Deep Convolutional Neural Network based Artifact Reduction](https://mlsanity.com/paper/2303.09340/) (2023)
- [Improving image quality of sparse-view lung tumor CT images with U-Net](https://mlsanity.com/paper/2307.15506/) (2023)

## Abstract (arXiv)

This study aims to investigate the effect of various beam geometries and dimensions of input data on the sparse-sampling streak artifact correction task with U-Nets for clinical CT scans as a means of incorporating the volumetric context into artifact reduction tasks to improve model performance. A total of 22 subjects were retrospectively selected (01.2016-12.2018) from the Technical University of Munich's research hospital, TUM Klinikum rechts der Isar. Sparsely-sampled CT volumes were simulated with the Astra toolbox for parallel, fan, and cone beam geometries. 2048 views were taken as full-view scans. 2D and 3D U-Nets were trained and validated on 14, and tested on 8 subjects, respectively. For the dimensionality study, in addition to the 512x512 2D CT images, the CT scans were further pre-processed to generate a so-called '2.5D', and 3D data: Each CT volume was divided into 64x64x64 voxel blocks. The 3D data refers to individual 64-voxel blocks. An axial, coronal, and sagittal cut through the center of each block resulted in three 64x64 2D patches that were rearranged as a single 64x64x3 image, proposed as 2.5D data. Model performance was assessed with the mean squared error (MSE) and structural similarity index measure (SSIM). For all geometries, the 2D U-Net trained on axial 2D slices results in the best MSE and SSIM values, outperforming the 2.5D and 3D input data dimensions.
