# Deep Learning Architectures for Medical Image Denoising: A Comparative Study of CNN-DAE, CADTra, and DCMIEDNet

arXiv: https://arxiv.org/abs/2508.17223 · HTML: https://mlsanity.com/paper/2508.17223/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 9 of its 40 references that are in the map.
- First posted on arXiv 24 Aug 2025.

## Builds on (most cited first, 9 of 9)

- [SwinIR: Image Restoration Using Swin Transformer](https://mlsanity.com/paper/2108.10257/) (2021)
- [Noise2Noise: Learning Image Restoration without Clean Data](https://mlsanity.com/paper/1803.04189/) (2018)
- [Plug-and-Play Image Restoration with Deep Denoiser Prior](https://mlsanity.com/paper/2008.13751/) (2020)
- [Multi-level Wavelet-CNN for Image Restoration](https://mlsanity.com/paper/1805.07071/) (2018)
- [Deep Learning on Image Denoising: An overview](https://mlsanity.com/paper/1912.13171/) (2019)
- [Diffusion Probabilistic Models beat GANs on Medical Images](https://mlsanity.com/paper/2212.07501/) (2022)
- [Medical image denoising using convolutional denoising autoencoders](https://mlsanity.com/paper/1608.04667/) (2016)
- [Multi-stage image denoising with the wavelet transform](https://mlsanity.com/paper/2209.12394/) (2022)
- [The role of noise in denoising models for anomaly detection in medical images](https://mlsanity.com/paper/2301.08330/) (2023)

## Abstract (arXiv)

Medical imaging modalities are inherently susceptible to noise contamination that degrades diagnostic utility and clinical assessment accuracy. This paper presents a comprehensive comparative evaluation of three state-of-the-art deep learning architectures for MRI brain image denoising: CNN-DAE, CADTra, and DCMIEDNet. We systematically evaluate these models across multiple Gaussian noise intensities (σ = 10, 15, 25) using the Figshare MRI Brain Dataset. Our experimental results demonstrate that DCMIEDNet achieves superior performance at lower noise levels, with PSNR values of 32.921 ± 2.350 dB and 30.943 ± 2.339 dB for σ = 10 and 15 respectively. However, CADTra exhibits greater robustness under severe noise conditions (σ = 25), achieving the highest PSNR of 27.671 ± 2.091 dB. All deep learning approaches significantly outperform traditional wavelet-based methods, with improvements ranging from 5-8 dB across tested conditions. This study establishes quantitative benchmarks for medical image denoising and provides insights into architecture-specific strengths for varying noise intensities.
