# Real-Time Reconstruction of 3D Bone Models via Very-Low-Dose Protocols

arXiv: https://arxiv.org/abs/2508.13947 · HTML: https://mlsanity.com/paper/2508.13947/

## Key facts

- Cited by 1 papers in the map (data through 14 Oct 2026).
- Builds on 7 of its 56 references that are in the map.
- First posted on arXiv 19 Aug 2025.

## Builds on (most cited first, 7 of 7)

- [PyTorch: An Imperative Style, High-Performance Deep Learning Library](https://mlsanity.com/paper/1912.01703/) (2019)
- [U-Net: Convolutional Networks for Biomedical Image Segmentation](https://mlsanity.com/paper/1505.04597/) (2015)
- [DeepSDF: Learning Continuous Signed Distance Functions for Shape Representation](https://mlsanity.com/paper/1901.05103/) (2019)
- [V-Net: Fully Convolutional Neural Networks for Volumetric Medical Image Segmentation](https://mlsanity.com/paper/1606.04797/) (2016)
- [Occupancy Networks: Learning 3D Reconstruction in Function Space](https://mlsanity.com/paper/1812.03828/) (2018)
- [Stacked Hourglass Networks for Human Pose Estimation](https://mlsanity.com/paper/1603.06937/) (2016)
- [End-To-End Convolutional Neural Network for 3D Reconstruction of Knee Bones From Bi-Planar X-Ray Images](https://mlsanity.com/paper/2004.00871/) (2020)

## Built on by (most cited first, 1 of 1)

- [Learning Where and What to Lift for Bi-planar X-ray-to-CT Reconstruction](https://mlsanity.com/paper/2608.17255/) (2026)

## Abstract (arXiv)

Patient-specific bone models are essential for designing surgical guides and preoperative planning, as they enable the visualization of intricate anatomical structures. However, traditional CT-based approaches for creating bone models are limited to preoperative use due to the low flexibility and high radiation exposure of CT and time-consuming manual delineation. Here, we introduce Semi-Supervised Reconstruction with Knowledge Distillation (SSR-KD), a fast and accurate AI framework to reconstruct high-quality bone models from biplanar X-rays in 30 seconds, with an average error under 1.0 mm, eliminating the dependence on CT and manual work. Additionally, high tibial osteotomy simulation was performed by experts on reconstructed bone models, demonstrating that bone models reconstructed from biplanar X-rays have comparable clinical applicability to those annotated from CT. Overall, our approach accelerates the process, reduces radiation exposure, enables intraoperative guidance, and significantly improves the practicality of bone models, offering transformative applications in orthopedics.