# AST-n: A Fast Sampling Approach for Low-Dose CT Reconstruction using Diffusion Models

arXiv: https://arxiv.org/abs/2508.09943 · HTML: https://mlsanity.com/paper/2508.09943/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Placed in Medical imaging and segmentation, one of 14 directions in Diffusion models.
- Builds on 8 of its 15 references that are in the map.
- First posted on arXiv 13 Aug 2025.

## Placed in

- Diffusion models / [Medical imaging and segmentation](https://mlsanity.com/diffusion/medical-imaging-and-segmentation/)

## Builds on (most cited first, 8 of 8)

- [Denoising Diffusion Probabilistic Models](https://mlsanity.com/paper/2006.11239/) (2020)
- [DPM-Solver: A Fast ODE Solver for Diffusion Probabilistic Model Sampling in Around 10 Steps](https://mlsanity.com/paper/2206.00927/) (2022)
- [Null-text Inversion for Editing Real Images using Guided Diffusion Models](https://mlsanity.com/paper/2211.09794/) (2022)
- [UniPC: A Unified Predictor-Corrector Framework for Fast Sampling of Diffusion Models](https://mlsanity.com/paper/2302.04867/) (2023)
- [Low Dose CT Image Denoising Using a Generative Adversarial Network with Wasserstein Distance and Perceptual Loss](https://mlsanity.com/paper/1708.00961/) (2017)
- [CoreDiff: Contextual Error-Modulated Generalized Diffusion Model for Low-Dose CT Denoising and Generalization](https://mlsanity.com/paper/2304.01814/) (2023)
- [ACDMSR: Accelerated Conditional Diffusion Models for Single Image Super-Resolution](https://mlsanity.com/paper/2307.00781/) (2023)
- [One Sample Diffusion Model in Projection Domain for Low-Dose CT Imaging](https://mlsanity.com/paper/2212.03630/) (2022)

## Abstract (arXiv)

Low-dose CT (LDCT) protocols reduce radiation exposure but increase image noise, compromising diagnostic confidence. Diffusion-based generative models have shown promise for LDCT denoising by learning image priors and performing iterative refinement. In this work, we introduce AST-n, an accelerated inference framework that initiates reverse diffusion from intermediate noise levels, and integrate high-order ODE solvers within conditioned models to further reduce sampling steps. We evaluate two acceleration paradigms--AST-n sampling and standard scheduling with high-order solvers -- on the Low Dose CT Grand Challenge dataset, covering head, abdominal, and chest scans at 10-25 % of standard dose. Conditioned models using only 25 steps (AST-25) achieve peak signal-to-noise ratio (PSNR) above 38 dB and structural similarity index (SSIM) above 0.95, closely matching standard baselines while cutting inference time from ~16 seg to under 1 seg per slice. Unconditional sampling suffers substantial quality loss, underscoring the necessity of conditioning. We also assess DDIM inversion, which yields marginal PSNR gains at the cost of doubling inference time, limiting its clinical practicality. Our results demonstrate that AST-n with high-order samplers enables rapid LDCT reconstruction without significant loss of image fidelity, advancing the feasibility of diffusion-based methods in clinical workflows.