# A Multi-Centric Anthropomorphic 3D CT Phantom-Based Benchmark Dataset for Harmonization

arXiv: https://arxiv.org/abs/2507.01539 · HTML: https://mlsanity.com/paper/2507.01539/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 9 of its 38 references that are in the map.
- First posted on arXiv 2 Jul 2025.

## Builds on (most cited first, 9 of 9)

- [An Image is Worth 16x16 Words: Transformers for Image Recognition at Scale](https://mlsanity.com/paper/2010.11929/) (2020)
- [Gaussian Error Linear Units (GELUs)](https://mlsanity.com/paper/1606.08415/) (2016)
- [The Many Faces of Robustness: A Critical Analysis of Out-of-Distribution Generalization](https://mlsanity.com/paper/2006.16241/) (2020)
- [Exploring Generalization in Deep Learning](https://mlsanity.com/paper/1706.08947/) (2017)
- [Self-Supervised Pre-Training of Swin Transformers for 3D Medical Image Analysis](https://mlsanity.com/paper/2111.14791/) (2021)
- [Learning Disentangled Representations in the Imaging Domain](https://mlsanity.com/paper/2108.12043/) (2021)
- [Contrastive Cross-site Learning with Redesigned Net for COVID-19 CT Classification](https://mlsanity.com/paper/2009.07652/) (2020)
- [Medical Image Harmonization Using Deep Learning Based Canonical Mapping: Toward Robust and Generalizable Learning in Imaging](https://mlsanity.com/paper/2010.05355/) (2020)
- [PrepNet: A Convolutional Auto-Encoder to Homogenize CT Scans for Cross-Dataset Medical Image Analysis](https://mlsanity.com/paper/2208.09408/) (2022)

## Abstract (arXiv)

Artificial intelligence (AI) has introduced numerous opportunities for human assistance and task automation in medicine. However, it suffers from poor generalization in the presence of shifts in the data distribution. In the context of AI-based computed tomography (CT) analysis, significant data distribution shifts can be caused by changes in scanner manufacturer, reconstruction technique or dose. AI harmonization techniques can address this problem by reducing distribution shifts caused by various acquisition settings. This paper presents an open-source benchmark dataset containing CT scans of an anthropomorphic phantom acquired with various scanners and settings, which purpose is to foster the development of AI harmonization techniques. Using a phantom allows fixing variations attributed to inter- and intra-patient variations. The dataset includes 1378 image series acquired with 13 scanners from 4 manufacturers across 8 institutions using a harmonized protocol as well as several acquisition doses. Additionally, we present a methodology, baseline results and open-source code to assess image- and feature-level stability and liver tissue classification, promoting the development of AI harmonization strategies.
