# Robust Body Composition Analysis by Generating 3D CT Volumes from Limited 2D Slices

arXiv: https://arxiv.org/abs/2501.13071 · HTML: https://mlsanity.com/paper/2501.13071/

## Key facts

- Cited by 1 papers in the map (data through 14 Oct 2026).
- Builds on 9 of its 24 references that are in the map.
- First posted on arXiv 22 Jan 2025.

## Builds on (most cited first, 9 of 9)

- [Denoising Diffusion Probabilistic Models](https://mlsanity.com/paper/2006.11239/) (2020)
- [U-Net: Convolutional Networks for Biomedical Image Segmentation](https://mlsanity.com/paper/1505.04597/) (2015)
- [High-Resolution Image Synthesis with Latent Diffusion Models](https://mlsanity.com/paper/2112.10752/) (2021)
- [Improved Denoising Diffusion Probabilistic Models](https://mlsanity.com/paper/2102.09672/) (2021)
- [RePaint: Inpainting using Denoising Diffusion Probabilistic Models](https://mlsanity.com/paper/2201.09865/) (2022)
- [TotalSegmentator: robust segmentation of 104 anatomical structures in CT images](https://mlsanity.com/paper/2208.05868/) (2022)
- [MONAI: An open-source framework for deep learning in healthcare](https://mlsanity.com/paper/2211.02701/) (2022)
- [Disentangling A Single MR Modality](https://mlsanity.com/paper/2205.04982/) (2022)
- [Reducing Positional Variance in Cross-sectional Abdominal CT Slices with Deep Conditional Generative Models](https://mlsanity.com/paper/2209.14467/) (2022)

## Built on by (most cited first, 1 of 1)

- [Diffusion Models in Medical Image Inpainting: Challenges, Solution Taxonomy, and Future Directions](https://mlsanity.com/paper/2607.21904/) (2026)

## Abstract (arXiv)

Body composition analysis provides valuable insights into aging, disease progression, and overall health conditions. Due to concerns of radiation exposure, two-dimensional (2D) single-slice computed tomography (CT) imaging has been used repeatedly for body composition analysis. However, this approach introduces significant spatial variability that can impact the accuracy and robustness of the analysis. To mitigate this issue and facilitate body composition analysis, this paper presents a novel method to generate 3D CT volumes from limited number of 2D slices using a latent diffusion model (LDM). Our approach first maps 2D slices into a latent representation space using a variational autoencoder. An LDM is then trained to capture the 3D context of a stack of these latent representations. To accurately interpolate intermediateslices and construct a full 3D volume, we utilize body part regression to determine the spatial location and distance between the acquired slices. Experiments on both in-house and public 3D abdominal CT datasets demonstrate that the proposed method significantly enhances body composition analysis compared to traditional 2D-based analysis, with a reduced error rate from 23.3% to 15.2%.
