# Subspace Implicit Neural Representations for Real-Time Cardiac Cine MR Imaging

arXiv: https://arxiv.org/abs/2412.12742 · HTML: https://mlsanity.com/paper/2412.12742/

## Key facts

- Cited by 4 papers in the map (data through 14 Oct 2026).
- Builds on 3 of its 45 references that are in the map.
- First posted on arXiv 17 Dec 2024.

## Builds on (most cited first, 3 of 3)

- [Spatiotemporal implicit neural representation for unsupervised dynamic MRI reconstruction](https://mlsanity.com/paper/2301.00127/) (2022)
- [Self-Score: Self-Supervised Learning on Score-Based Models for MRI Reconstruction](https://mlsanity.com/paper/2209.00835/) (2022)
- [Unsupervised reconstruction of accelerated cardiac cine MRI using Neural Fields](https://mlsanity.com/paper/2307.14363/) (2023)

## Built on by (most cited first, 4 of 4)

- [KP-INR: A Dual-Branch Implicit Neural Representation Model for Cardiac Cine MRI Reconstruction](https://mlsanity.com/paper/2508.12147/) (2025)
- [Low-Rank Augmented Implicit Neural Representation for Unsupervised High-Dimensional Quantitative MRI Reconstruction](https://mlsanity.com/paper/2506.09100/) (2025)
- [No Image, No Problem: End-to-End Multi-Task Cardiac Analysis from Undersampled k-Space](https://mlsanity.com/paper/2603.09945/) (2026)
- [MoE-dqINR: A Unified Mixture-of-Experts Implicit Neural Representation Framework for Scan-Specific Dynamic and Quantitative MRI Reconstruction](https://mlsanity.com/paper/2605.31302/) (2026)

## Abstract (arXiv)

Conventional cardiac cine MRI methods rely on retrospective gating, which limits temporal resolution and the ability to capture continuous cardiac dynamics, particularly in patients with arrhythmias and beat-to-beat variations. To address these challenges, we propose a reconstruction framework based on subspace implicit neural representations for real-time cardiac cine MRI of continuously sampled radial data. This approach employs two multilayer perceptrons to learn spatial and temporal subspace bases, leveraging the low-rank properties of cardiac cine MRI. Initialized with low-resolution reconstructions, the networks are fine-tuned using spoke-specific loss functions to recover spatial details and temporal fidelity. Our method directly utilizes the continuously sampled radial k-space spokes during training, thereby eliminating the need for binning and non-uniform FFT. This approach achieves superior spatial and temporal image quality compared to conventional binned methods at the acceleration rate of 10 and 20, demonstrating potential for high-resolution imaging of dynamic cardiac events and enhancing diagnostic capability.
