# Joint image reconstruction and segmentation of real-time cardiac MRI in free-breathing using a model based on disentangled representation learning

arXiv: https://arxiv.org/abs/2409.08619 · HTML: https://mlsanity.com/paper/2409.08619/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 5 of its 33 references that are in the map.
- First posted on arXiv 13 Sep 2024.

## Builds on (most cited first, 5 of 5)

- [U-Net: Convolutional Networks for Biomedical Image Segmentation](https://mlsanity.com/paper/1505.04597/) (2015)
- [Perceptual Losses for Real-Time Style Transfer and Super-Resolution](https://mlsanity.com/paper/1603.08155/) (2016)
- [FiLM: Visual Reasoning with a General Conditioning Layer](https://mlsanity.com/paper/1709.07871/) (2017)
- [Disentangled Representation Learning in Cardiac Image Analysis](https://mlsanity.com/paper/1903.09467/) (2019)
- [HyperSLICE: HyperBand optimized Spiral for Low-latency Interactive Cardiac Examination](https://mlsanity.com/paper/2302.02688/) (2023)

## Abstract (arXiv)

A joint image reconstruction and segmentation approach based on disentangled representation learning was trained to enable cardiac cine MR imaging in real-time and under free-breathing. An exploratory feasibility study tested the proposed method in undersampled real-time acquisitions based on an in-house developed spiral bSSFP pulse sequence in eight healthy participants and five patients with intermittent atrial fibrillation. Images and predicted LV segmentations were compared to the reference standard of ECG-gated segmented Cartesian cine in repeated breath-holds and corresponding manual segmentation. On a 5-point Likert scale, image quality of the real-time breath-hold approach and Cartesian cine was comparable in healthy participants (RT-BH: 1.99 ± .98, Cartesian: 1.94 ± .86, p=.052), but slightly inferior in free-breathing (RT-FB: 2.40 ± .98, p<.001). In patients with arrhythmia, image quality from both real-time approaches was favourable (RT-BH: 2.10 ± 1.28, p<.001, RT-FB: 2.40 ± 1.13, p<.001, Cartesian: 2.68 ± 1.13). Intra-observer reliability was good (ICC=.77, 95%-confidence interval [.75, .79], p<.001). In functional analysis, a positive bias was observed for ejection fractions derived from the proposed model compared to the clinical reference standard (RT-BH mean EF: 58.5 ± 5.6%, bias: +3.47%, 95%-confidence interval [-.86, 7.79%], RT-FB mean: 57.9 ± 10.6%, bias: +1.45%, [-3.02, 5.91%], Cartesian mean: 54.9 ± 6.7%). The introduced real-time MR imaging technique is capable of acquiring high-quality cardiac cine data in 1-2 minutes without the need for ECG gating and breath-holds. It thus offers a promising alternative to the current clinical practice of segmented acquisition, with shorter scan times, higher patient comfort and increased robustness to arrhythmia and patient incompliance.
