# GuidedRec: Guiding Ill-Posed Unsupervised Volumetric Recovery

arXiv: https://arxiv.org/abs/2405.11977 · HTML: https://mlsanity.com/paper/2405.11977/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 12 of its 36 references that are in the map.
- First posted on arXiv 20 May 2024.

## Builds on (most cited first, 12 of 12)

- [Attention Is All You Need](https://mlsanity.com/paper/1706.03762/) (2017)
- [U-Net: Convolutional Networks for Biomedical Image Segmentation](https://mlsanity.com/paper/1505.04597/) (2015)
- [Perceptual Losses for Real-Time Style Transfer and Super-Resolution](https://mlsanity.com/paper/1603.08155/) (2016)
- [3D U-Net: Learning Dense Volumetric Segmentation from Sparse Annotation](https://mlsanity.com/paper/1606.06650/) (2016)
- [Spatial Transformer Networks](https://mlsanity.com/paper/1506.02025/) (2015)
- [VoxelMorph: A Learning Framework for Deformable Medical Image Registration](https://mlsanity.com/paper/1809.05231/) (2018)
- [NeRP: Implicit Neural Representation Learning with Prior Embedding for Sparsely Sampled Image Reconstruction](https://mlsanity.com/paper/2108.10991/) (2021)
- [NAF: Neural Attenuation Fields for Sparse-View CBCT Reconstruction](https://mlsanity.com/paper/2209.14540/) (2022)
- [X2CT-GAN: Reconstructing CT from Biplanar X-Rays with Generative Adversarial Networks](https://mlsanity.com/paper/1905.06902/) (2019)
- [A Geometry-Informed Deep Learning Framework for Ultra-Sparse 3D Tomographic Image Reconstruction](https://mlsanity.com/paper/2105.11692/) (2021)
- [Fluid registration between lung CT and stationary chest tomosynthesis images](https://mlsanity.com/paper/2203.04958/) (2022)
- [LiftReg: Limited Angle 2D/3D Deformable Registration](https://mlsanity.com/paper/2203.05565/) (2022)

## Abstract (arXiv)

We introduce a novel unsupervised approach to reconstructing a 3D volume from only two planar projections that exploits a previous-ly-captured 3D volume of the patient. Such volume is readily available in many important medical procedures and previous methods already used such a volume. Earlier methods that work by deforming this volume to match the projections typically fail when the number of projections is very low as the alignment becomes underconstrained. We show how to use a generative model of the volume structures to constrain the deformation and obtain a correct estimate. Moreover, our method is not bounded to a specific sensor calibration and can be applied to new calibrations without retraining. We evaluate our approach on a challenging dataset and show it outperforms state-of-the-art methods. As a result, our method could be used in treatment scenarios such as surgery and radiotherapy while drastically reducing patient radiation exposure.
