# Fine-tuning pre-trained extractive QA models for clinical document parsing

arXiv: https://arxiv.org/abs/2312.02314 · HTML: https://mlsanity.com/paper/2312.02314/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 9 of its 17 references that are in the map.
- First posted on arXiv 4 Dec 2023.

## Builds on (most cited first, 9 of 9)

- [Attention Is All You Need](https://mlsanity.com/paper/1706.03762/) (2017)
- [DistilBERT, a distilled version of BERT: smaller, faster, cheaper and lighter](https://mlsanity.com/paper/1910.01108/) (2019)
- [SQuAD: 100,000+ Questions for Machine Comprehension of Text](https://mlsanity.com/paper/1606.05250/) (2016)
- [VQA: Visual Question Answering](https://mlsanity.com/paper/1505.00468/) (2015)
- [Know What You Don't Know: Unanswerable Questions for SQuAD](https://mlsanity.com/paper/1806.03822/) (2018)
- [MLQA: Evaluating Cross-lingual Extractive Question Answering](https://mlsanity.com/paper/1910.07475/) (2019)
- [emrQA: A Large Corpus for Question Answering on Electronic Medical Records](https://mlsanity.com/paper/1809.00732/) (2018)
- [CliCR: A Dataset of Clinical Case Reports for Machine Reading Comprehension](https://mlsanity.com/paper/1803.09720/) (2018)
- [Pre-trained Language Model for Biomedical Question Answering](https://mlsanity.com/paper/1909.08229/) (2019)

## Abstract (arXiv)

Electronic health records (EHRs) contain a vast amount of high-dimensional multi-modal data that can accurately represent a patient's medical history. Unfortunately, most of this data is either unstructured or semi-structured, rendering it unsuitable for real-time and retrospective analyses. A remote patient monitoring (RPM) program for Heart Failure (HF) patients needs to have access to clinical markers like EF (Ejection Fraction) or LVEF (Left Ventricular Ejection Fraction) in order to ascertain eligibility and appropriateness for the program. This paper explains a system that can parse echocardiogram reports and verify EF values. This system helps identify eligible HF patients who can be enrolled in such a program. At the heart of this system is a pre-trained extractive QA transformer model that is fine-tuned on custom-labeled data. The methods used to prepare such a model for deployment are illustrated by running experiments on a public clinical dataset like MIMIC-IV-Note. The pipeline can be used to generalize solutions to similar problems in a low-resource setting. We found that the system saved over 1500 hours for our clinicians over 12 months by automating the task at scale.
