# Deep-Learning-based Fast and Accurate 3D CT Deformable Image Registration in Lung Cancer

arXiv: https://arxiv.org/abs/2304.11135 · HTML: https://mlsanity.com/paper/2304.11135/

## Key facts

- Cited by 10 papers in the map (data through 14 Oct 2026).
- Builds on 5 of its 101 references that are in the map.
- First posted on arXiv 21 Apr 2023.

## Builds on (most cited first, 5 of 5)

- [Masked Autoencoders Are Scalable Vision Learners](https://mlsanity.com/paper/2111.06377/) (2021)
- [VoxelMorph: A Learning Framework for Deformable Medical Image Registration](https://mlsanity.com/paper/1809.05231/) (2018)
- [A Deep Learning Framework for Unsupervised Affine and Deformable Image Registration](https://mlsanity.com/paper/1809.06130/) (2018)
- [Quicksilver: Fast Predictive Image Registration - a Deep Learning Approach](https://mlsanity.com/paper/1703.10908/) (2017)
- [Recursive Cascaded Networks for Unsupervised Medical Image Registration](https://mlsanity.com/paper/1907.12353/) (2019)

## Built on by (most cited first, 10 of 10)

- [Large Language Models for Robotics: Opportunities, Challenges, and Perspectives](https://mlsanity.com/paper/2401.04334/) (2024)
- [Review of Large Vision Models and Visual Prompt Engineering](https://mlsanity.com/paper/2307.00855/) (2023)
- [Radiology-Llama2: Best-in-Class Large Language Model for Radiology](https://mlsanity.com/paper/2309.06419/) (2023)
- [Segment Anything Model (SAM) for Radiation Oncology](https://mlsanity.com/paper/2306.11730/) (2023)
- [Evaluating Large Language Models for Radiology Natural Language Processing](https://mlsanity.com/paper/2307.13693/) (2023)
- [Hierarchical Semantic Tree Concept Whitening for Interpretable Image Classification](https://mlsanity.com/paper/2307.04343/) (2023)
- [PharmacyGPT: The AI Pharmacist](https://mlsanity.com/paper/2307.10432/) (2023)
- [Noisy probing dose facilitated dose prediction for pencil beam scanning proton therapy: physics enhances generalizability](https://mlsanity.com/paper/2312.00975/) (2023)
- [Accurate Patient Alignment without Unnecessary Imaging Dose via Synthesizing Patient-specific 3D CT Images from 2D kV Images](https://mlsanity.com/paper/2405.19338/) (2024)
- [Learning Semi-Supervised Medical Image Segmentation from Spatial Registration](https://mlsanity.com/paper/2409.10422/) (2024)

## Abstract (arXiv)

Purpose: In some proton therapy facilities, patient alignment relies on two 2D orthogonal kV images, taken at fixed, oblique angles, as no 3D on-the-bed imaging is available. The visibility of the tumor in kV images is limited since the patient's 3D anatomy is projected onto a 2D plane, especially when the tumor is behind high-density structures such as bones. This can lead to large patient setup errors. A solution is to reconstruct the 3D CT image from the kV images obtained at the treatment isocenter in the treatment position. Methods: An asymmetric autoencoder-like network built with vision-transformer blocks was developed. The data was collected from 1 head and neck patient: 2 orthogonal kV images (1024x1024 voxels), 1 3D CT with padding (512x512x512) acquired from the in-room CT-on-rails before kVs were taken and 2 digitally-reconstructed-radiograph (DRR) images (512x512) based on the CT. We resampled kV images every 8 voxels and DRR and CT every 4 voxels, thus formed a dataset consisting of 262,144 samples, in which the images have a dimension of 128 for each direction. In training, both kV and DRR images were utilized, and the encoder was encouraged to learn the jointed feature map from both kV and DRR images. In testing, only independent kV images were used. The full-size synthetic CT (sCT) was achieved by concatenating the sCTs generated by the model according to their spatial information. The image quality of the synthetic CT (sCT) was evaluated using mean absolute error (MAE) and per-voxel-absolute-CT-number-difference volume histogram (CDVH). Results: The model achieved a speed of 2.1s and a MAE of <40HU. The CDVH showed that <5% of the voxels had a per-voxel-absolute-CT-number-difference larger than 185 HU. Conclusion: A patient-specific vision-transformer-based network was developed and shown to be accurate and efficient to reconstruct 3D CT images from kV images.
